Table 1.1 | SAS RAID Controller Array Limitations |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| 9280 4i/4e | ||||||
Specification |
| SAS | SAS | SAS | SAS | SAS | SAS | SAS |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Maximum drives per | 16* | 16* | 32 | 32 | 32 | 240 | 240 | |
controller |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Maximum hot spares | 8 | 8 | 32 | 32 | 32 | 240 | 240 | |
per controller |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Maximum spans per | 8 | 8 | 8 | 8 | 8 | 8 | 8 | |
virtual drive |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Maximum enclosures | 2 | 2 | 2 | 2 | 2 | 10 | 10 | |
per port** |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Number of ports | 1 | 2 | 1 | 2 | 2 | 2 | 2 | |
|
|
|
|
|
|
|
|
|
*- Can support up to 64 devices, but only 16 can be used in a RAID configuration.
**- Assumes one Storage Enclosure Processor (SEP) per enclosure.
The maximum numbers in Table 1.1 depend on how many physical devices you have connected to the RAID controller. For example, the maximum number of drive groups is equal to the number of drives supported by the controller. Thus, for the SAS
Although you can have up to 16 virtual drives per drive group and up to 16 drive groups per controller (depending on the controller), there is a limit of 64 virtual drives per controller.
These RAID controllers support
1-12 Overview