will need to purchase an optional current sensor (Part # M000630) for monitoring this type of system.

Step 1: De-energize the AC Source.

Step 2: The Current Transformer has black and white wires. Install the Phase A Current Transformer as follows:

a.Connect the black wire to pin 7 (IA+) on the ACM100

b.Connect the white wire to pin 8 (IA-) on the ACM100

c.Disconnect the Phase A hot wire from the AC power source and place it through the hole in the Current Sensor such that the arrow on the Current Sensor points towards the AC power source. Then, reattach the hot wire to the AC power source.

Step 3: Repeat step 2 for the Phase B Current Transformer as follows:

a.Connect the black wire to pin 9 (IB+) on the ACM100

b.Connect the white wire to pin 10 (IB-) on the ACM100

c.Disconnect the Phase B hot wire from the AC power source and place it through the hole in the Current Sensor such that the arrow on the Current Sensor points towards the AC power source. Then, reattach the hot wire to the AC power source.

Step 4: You must supply cables for connecting the voltage sense pins on the ACM100 to the AC source. For the purposes of these instructions, we will assume that each cable has one black conductor and one white conductor. Install the first voltage sense cable as follows:

a.Connect the white wire from one end of the first Voltage Sense cable to pin 4 (VANeutral) on the ACM100.

b.Connect the white wire from the other end of the first Voltage Sense cable to the neutral wire of the AC source being monitored

c.Connect the black wire from one end of the first Voltage Sense cable to pin 1 (VALine) on the ACM100

d.Connect the black wire from the other end of the first Voltage Sense cable to a fuse appropriately sized for the black wire (18 gauge wire minimum and 3 amp fuse or less).

e.Connect the other end of the fuse to the AC source hot wire (the fuse should be placed within 6 inches of the connection to the hot wire).

Step 5: Install the second Voltage Sense cable as follows:

a.Connect the white wire from one end of the second Voltage Sense cable to pin 5 (VBNeutral) on the ACM100.

b.Connect the white wire from the other end of the second Voltage Sense cable to the neutral wire of the AC source being monitored.

c.Connect the black wire from one end of the second Voltage Sense cable to pin 2 (VBLine) on the ACM100

d.Connect the black wire from the other end of the second Voltage Sense cable to a fuse appropriately sized for the black wire (18 gauge wire minimum and 3 amp fuse or less).

e.Connect the other end of the fuse to the AC source hot wire (the fuse should be placed within 6 inches of the connection to the hot wire).

Revision 1.2

Page 7

Image 11
Contents Maretron, LLP 9014 N. 23rd Ave #10 RevisionPage Revision Copyright 2012 Maretron, LLP All Rights ReservedRevision Revision HistoryACM100 User’s Manual PageTable of Figures Table of ContentsMounting Surface Template Table of AppendicesSingle-Phase Dual Line Connection Diagram Three-Phase Connection Diagram1.1 Firmware Revision 1.2 ACM100 Features1 Introduction 2.2 Choosing a Mounting Location 2 Installation1.3 Quick Install 2.1 Unpacking the Box2.4.1 NMEA 2000 Connection 2.4 Connecting the ACM1002.3 Mounting the ACM100 Connection Pin # Signal Name2.4.2 AC Sensor Connections AC Source 2.4.2.1 Single-Phase Phase A Connection2.4.2.2 Single-Phase Phase A, B Connection Page Figure 5 - Three-Phase Connection Diagram 2.4.2.3 Three-Phase Phase A, B, C ConnectionPage 2.5.2 AC Device Type 2.5 Configuring the ACM1002.4.3 Checking Connections 2.5.1 Device Instance2.5.3 AC Circuit Type 2.5.4 Reset Total Energy Recorded2.5.5 Advanced Configuration… 2.5.5.3 Power Damping Period2.5.5.5 Current Transformer B 2.5.6 NMEA 2000 PGN Enable/Disable2.5.7 Restore Factory Defaults 3 Output Parameters3.2 Line-to-Line Measurements 4 Maintenance3.1 Line-Specific and Line-to-Neutral Measurements Troubleshooting Procedure 5 TroubleshootingSymptom Default Rate 6 Technical SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNsEnvironmental 7 Technical SupportElectrical MechanicalFigure 6 - Mounting Surface Template 8 Installation TemplateWarranty Return Procedure 9 Maretron 2 Year Limited WarrantyPage A1 Appendix A - NMEA 2000 InterfacingACM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 InterfacingPGN 65005 - Utility Total AC Energy Page A2