![PGN 65005 – Utility Total AC Energy](/images/new-backgrounds/157759/15775947x1.webp)
ACM100 User’s Manual
PGN 65005 – Utility Total AC Energy
PGN 65018 – Generator Total AC Energy
The ACM100 uses this PGN to transmit the total energy delivered by the power source.
Field 1: Total kWh Hours Export – This field indicates the total energy delivered by the AC power source in units of 1 kWh.
2:Total kWh Hours Import – This field indicates the total energy delivered to the AC power source in units of 1 kWh.
PGN 65007 – Utility Phase C AC Power
PGN 65010 – Utility Phase B AC Power
PGN 65013 – Utility Phase A AC Power
PGN 65016 – Utility Total AC Power
PGN 65020 – Generator Phase C AC Power
PGN 65023 – Generator Phase B AC Power
PGN 65026 – Generator Phase A AC Power
PGN 65029 – Generator Total AC Power
The ACM100 uses these PGNs to transmit the total real power and apparent power (the vector sum of real power and reactive power).
Field 1: Real Power – This field indicates the real power delivered by the AC power source in units of 1W.
2:Apparent Power – This field indicates the apparent power delivered by the AC power source in units of 1 VA.
Page A2 | Appendix A – NMEA 2000 Interfacing | Revision 1.2 |