2.3 Mounting the ACM100

®

2.3 Mounting the ACM100

Attach the ACM100 securely to the vessel using the included stainless steel mounting screws or other fasteners as shown in Figure 1 below. Do not use threadlocking compounds containing methacrylate ester, such as Loctite Red (271), as they will cause stress cracking of the plastic enclosure.

Figure 1 – Mounting the ACM100

2.4 Connecting the ACM100

The ACM100 requires two types of electrical connections: 1) the NMEA 2000® connection (refer to Section 2.4.1), and 2) the AC sensor connections (i.e., current sensor(s) and sensing voltage(s) connections), which are described in Section 2.4.2.

2.4.1 NMEA 2000® Connection

The NMEA 2000® connector can be found on the side of the enclosure. The NMEA 2000® connector is a round five pin male connector (see Figure 2). You connect the ACM100 to an NMEA 2000® network using a Maretron NMEA 2000® cable (or compatible cable) by connecting the female end of the cable to the ACM100 (note the key on the male connector and keyway on the female connector). Be sure the cable is connected securely and that the collar on the cable connector is tightened firmly. Connect the other end of the cable (male) to the NMEA 2000® network in the same manner. The ACM100 is designed such that you can plug or unplug it from an NMEA 2000® network while the power to the network is connected or disconnected. Please follow recommended practices for installing NMEA 2000® network products.

Revision 1.2

Page 3

Image 7
Contents Maretron, LLP 9014 N. 23rd Ave #10 RevisionPage Revision Copyright 2012 Maretron, LLP All Rights ReservedRevision Revision HistoryACM100 User’s Manual PageTable of Figures Table of ContentsMounting Surface Template Table of AppendicesSingle-Phase Dual Line Connection Diagram Three-Phase Connection Diagram1 Introduction 1.2 ACM100 Features1.1 Firmware Revision 2.2 Choosing a Mounting Location 2 Installation1.3 Quick Install 2.1 Unpacking the Box2.3 Mounting the ACM100 2.4 Connecting the ACM1002.4.1 NMEA 2000 Connection 2.4.2 AC Sensor Connections Pin # Signal NameConnection AC Source 2.4.2.1 Single-Phase Phase A Connection2.4.2.2 Single-Phase Phase A, B Connection Page Figure 5 - Three-Phase Connection Diagram 2.4.2.3 Three-Phase Phase A, B, C ConnectionPage 2.5.2 AC Device Type 2.5 Configuring the ACM1002.4.3 Checking Connections 2.5.1 Device Instance2.5.3 AC Circuit Type 2.5.4 Reset Total Energy Recorded2.5.5 Advanced Configuration… 2.5.5.3 Power Damping Period2.5.5.5 Current Transformer B 2.5.6 NMEA 2000 PGN Enable/Disable2.5.7 Restore Factory Defaults 3 Output Parameters3.1 Line-Specific and Line-to-Neutral Measurements 4 Maintenance3.2 Line-to-Line Measurements Symptom 5 TroubleshootingTroubleshooting Procedure Default Rate 6 Technical SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNsEnvironmental 7 Technical SupportElectrical MechanicalFigure 6 - Mounting Surface Template 8 Installation TemplateWarranty Return Procedure 9 Maretron 2 Year Limited WarrantyPage A1 Appendix A - NMEA 2000 InterfacingACM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 InterfacingPGN 65005 - Utility Total AC Energy Page A2