Maretron ACM100 Technical Specifications, Certifications, NMEA 2000 Parameter Group Numbers PGNs

Page 19
6 Technical Specifications

®

6 Technical Specifications

As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretron products are designed to be accurate and reliable; however, they should be used only as aids to navigation and not as a replacement for traditional navigation aids and techniques.

Certifications

Parameter

NMEA 2000®

Maritime Navigation and Radiocommunication Equipment & Systems

FCC and CE Mark

Comment

Level A

IEC 60945

Electromagnetic Compatibility

NMEA 2000® Parameter Group Numbers (PGNs)

Description

PGN #
PGN Name
Default Rate

Periodic Data PGNs

65001

Bus #1 Phase C Basic AC Quantities

10 times/second

 

65002

Bus #1 Phase B Basic AC Quantities

10 times/second

 

65003

Bus #1 Phase A Basic AC Quantities

10 times/second

 

65004

Bus #1 Average Basic AC Quantities

10 times/second

 

65005

Utility Total AC Energy

10 times/second

 

65006

Utility Phase C AC Reactive Power

10 times/second

 

65007

Utility Phase C AC Power

10 times/second

 

65008

Utility Phase C AC Basic Quantities

10 times/second

 

65009

Utility Phase B AC Reactive Power

10 times/second

 

65010

Utility Phase B AC Power

10 times/second

 

65011

Utility Phase B AC Basic Quantities

10 times/second

 

65012

Utility Phase A AC Reactive Power

10 times/second

 

65013

Utility Phase A AC Power

10 times/second

 

65014

Utility Phase A AC Basic Quantities

10 times/second

 

65015

Utility Total AC Reactive Power

10 times/second

 

65016

Utility Total AC Power

10 times/second

 

65017

Utility Average Basic AC Quantities

10 times/second

 

65018

Generator Total AC Energy

10 times/second

 

65019

Generator Phase C AC Reactive Power

10 times/second

 

65020

Generator Phase C AC Power

10 times/second

 

65021

Generator Phase C AC Basic Quantities

10 times/second

 

65022

Generator Phase B AC Reactive Power

10 times/second

 

65023

Generator Phase B AC Power

10 times/second

 

65024

Generator Phase B AC Basic Quantities

10 times/second

 

65025

Generator Phase A AC Reactive Power

10 times/second

 

65026

Generator Phase A AC Power

10 times/second

 

65027

Generator Phase A AC Basic Quantities

10 times/second

 

65028

Generator Total AC Reactive Power

10 times/second

 

65029

Generator Total AC Power

10 times/second

 

65030

Generator Average Basic AC Quantities

10 times/second

Response to Requested PGNs

126464

PGN List (Transmit and Receive)

N/A

 

126996

Product Information

N/A

 

126998

Configuration Information

N/A

Protocol PGNs

059392

ISO Acknowledge

N/A

 

059904

ISO Request

N/A

 

060928

ISO Address Claim

N/A

 

065240

ISO Address Command

N/A

 

126208

NMEA

N/A

Maretron Proprietary PGNs

128720

Configuration

N/A

 

 

 

 

Revision 1.2

 

 

Page 15

Image 19
Contents Maretron, LLP 9014 N. 23rd Ave #10 RevisionPage Revision Copyright 2012 Maretron, LLP All Rights ReservedRevision Revision HistoryACM100 User’s Manual PageTable of Figures Table of ContentsMounting Surface Template Table of AppendicesSingle-Phase Dual Line Connection Diagram Three-Phase Connection Diagram1 Introduction 1.2 ACM100 Features1.1 Firmware Revision 2.2 Choosing a Mounting Location 2 Installation1.3 Quick Install 2.1 Unpacking the Box2.3 Mounting the ACM100 2.4 Connecting the ACM1002.4.1 NMEA 2000 Connection 2.4.2 AC Sensor Connections Pin # Signal NameConnection AC Source 2.4.2.1 Single-Phase Phase A Connection2.4.2.2 Single-Phase Phase A, B Connection Page Figure 5 - Three-Phase Connection Diagram 2.4.2.3 Three-Phase Phase A, B, C ConnectionPage 2.5.2 AC Device Type 2.5 Configuring the ACM1002.4.3 Checking Connections 2.5.1 Device Instance2.5.3 AC Circuit Type 2.5.4 Reset Total Energy Recorded2.5.5 Advanced Configuration… 2.5.5.3 Power Damping Period2.5.5.5 Current Transformer B 2.5.6 NMEA 2000 PGN Enable/Disable2.5.7 Restore Factory Defaults 3 Output Parameters3.1 Line-Specific and Line-to-Neutral Measurements 4 Maintenance3.2 Line-to-Line Measurements Symptom 5 TroubleshootingTroubleshooting Procedure Default Rate 6 Technical SpecificationsCertifications NMEA 2000 Parameter Group Numbers PGNsEnvironmental 7 Technical SupportElectrical MechanicalFigure 6 - Mounting Surface Template 8 Installation TemplateWarranty Return Procedure 9 Maretron 2 Year Limited WarrantyPage A1 Appendix A - NMEA 2000 InterfacingACM100 NMEA 2000 Periodic Data Transmitted PGNs Appendix A - NMEA 2000 InterfacingPGN 65005 - Utility Total AC Energy Page A2