Lucent Technologies P333T manual Assigning Cajun P330’s IP Stack Address

Page 32

Chapter 4 Installation and Setup

Assigning Cajun P330’s IP Stack Address

Note: All Cajun P330 switches are shipped with the same default IP address. You must change the IP address of the master Cajun P330 switch in a stack in order to guarantee that the stack has its own unique IP address in the network.

Changing the IP Address using Command Line Interface (CLI, Terminal Emulation)

Use the CLI to assign the Cajun P330 stack an IP address and net mask. The CajunView station may establish communications with the stack once this address had been assigned and the stack inserted into the network.

1Establish a serial connection by connecting a terminal to the master Cajun P330 switch as described in the “Command Line Interface” chapter.

2When you see the “Welcome to P330” menu and are prompted for a password, enter the User Level password norm

3At the Console> prompt, enter enable to enter the Privileged level.

4Enter the password. The default is enable.

5At the Console>(enable) prompt, type:

set interface <inband> <vlan> <ip_address> <netmask> Replace <vlan>, <ip_address> and <netmask> with the VLAN, IP address and net mask of the stack.

6Press Enter to save the IP address and net mask.

7At the Console>(enable) prompt, enter reset and press Enter to reset the stack. After the Reset, perform login to Privileged level again as described above.

8At the Console>(enable) prompt, enter set ip route <dest><gateway> where you replace <dest> and <gateway> with the destination and gateway IP addresses.

9Press Enter to save the destination and gateway IP addresses.

Note: If there are any errors, the new configuration settings will not be saved. To save the new configuration settings, you must correct the errors by repeating the command.

10At the Console>(enable) prompt, type exit or disable with the password (default password norm ) to exit the Privileged level, and press Enter to confirm the command. The prompt changes to Console> to indicate that you are in User level.

11Exit the CLI session.

12Insert the Cajun P330 stack into your network.

22

Cajun P333T User’s Guide

Image 32
Contents Cajun P333T Page Contents Cajun P333T User’s Guide Mtbf Mtbf List of Figures Cajun P333T LEDsList of Figures Cajun P333T User’s Guide List of Tables List of Tables Viii Cajun P333T User’s Guide Cajun P330 Family Features OverviewLayer 2 Features Auto-NegotiationCongestion Control VLANsCajun P330 Standards Supported Cajun P330 Network Management DurabilityCajun P330 Manager CajunViewCajun P330 Network Monitoring Rmon MIBs RFCSmon MIBs RFC Port MirroringChapter Overview Cajun P333T User’s Guide Cajun P333T Front and Rear Panels Cajun P333T Front PanelPWR FDX Cajun P333T Back Panel Cajun P333T AC and DC Back PanelsApplications ApplicationCajun P330 stacks with a Cajun 330 backbone Installation and Setup Installing Stacking Sub-modulesInstalling the Stacking Sub-module in the Cajun P330 PositioningRack Mounting Cajun P333T Rack MountingConnecting Stacked Switches To connect stacked switchesIncorrect Stack Connection Removing an Existing Expansion Sub-module Installing Expansion Sub-modulesInstalling the Expansion Sub-module into the Cajun P330 Powering On Cajun P330 Module AC Powering On Cajun P330 Module DCConfiguring the Switch Cajun P330 Default SettingsCabling Connecting to the Serial Port 1000BASE-SLXAssigning Cajun P330’s IP Stack Address Conventions Used Cajun Campus CLI Command Line InterfaceEstablishing a Serial Connection for Configuration Establishing a Telnet Session For example telnetRunning the CLI Security Levels Entering the User LevelEntering the Privileged Level Entering the Supervisor LevelGeneral Commands Top and Up commandsRetstatus command Tree commandCommand Syntax Command AbbreviationsNavigation, Cursor Movement and Shortcuts Getting HelpHow Commands are Organized Commands, Parameters and Default SettingsCommand Hierarchy Cajun Campus CLI Command Line Interface Flowcontrol Trunk Vlan User Level Commands Show time commandShow timeout command Show timezone commandShow image version command Show ntp commandShow system command Show snmp command Show interface command Show port commandField Description Show module commandShow module command Show flowcontrol command Console show flowcontrolShow cam command FieldShow trunk command Show spantree command Show log command AddrShow download status command Privileged Level Commands Disable commandSet commands Set enablepass commandSet ip route command Set logout commandSet ntp server command Set snmp community command Set snmp community read-onlyreadSet snmp trap command Set snmp trap rcvraddrSet system location command Set system name commandSet system location string Set system name stringSet system contact command Set interface commandSet port level command Set system contact stringSet port negotiation command Set port enable commandSet port duplex command Set port disable commandSet port speed command Set Vlan command Set flowcontrol command Set trunk command Set spantree priority command Set spantree enable commandSet spantree disable command Set Smon License Command Sync time commandGet time command Clear CommandsClear cam command Clear snmp trap commandClear Vlan command Download command Reset commandTo reset module Set defpass command Supervisor Level CommandsSet super password command Specifications Cajun P330 SwitchPower Requirements AC Power Requirements DCSafety AC Safety DCEnvironmental EMC EmissionsLaser Safety Stacking Sub-moduleExpansion Sub-modules Standards ComplianceLaser Data Laser ClassificationUsage Restriction Fast Ethernet Fiber Expansion Sub-module Ethernet/Fast Ethernet Expansion Sub-moduleBackup Power Supply Bups Power RequirementsSafety Mtbf System Requirements InstallationCajun P330 Standalone Manager Documentation and Online Help Software DownloadHow to Contact Us +972 3 645Cajun P333T User’s Guide
Related manuals
Manual 12 pages 58.95 Kb

P333T specifications

Lucent Technologies P333T is a highly regarded networking device that has made significant contributions to the telecommunications field. Primarily designed for service providers and large organizations, it is recognized for its robust architecture, which is tailored to handle high-capacity data processing and seamless voice integration.

One of the standout features of the P333T is its support for multiple types of network interfaces, including Ethernet and ATM. This versatility allows organizations to integrate the device into various types of network environments, thereby ensuring compatibility with existing infrastructure. Additionally, the P333T supports both IP and legacy protocols, making it suitable for a wide range of applications and use cases.

The P333T is equipped with advanced packet processing capabilities, enabling efficient data handling and routing. This is particularly important in today's data-driven world, where fast and reliable connections are paramount. The multi-service capabilities of the P333T allow it to effectively manage voice, video, and data traffic simultaneously, thus optimizing the overall performance of the network.

Another significant attribute of the P333T is its modular design. This feature enables organizations to easily upgrade or replace components according to their evolving needs. The ability to scale up as required is essential for businesses looking to future-proof their investments and ensure longevity in their network solutions.

In terms of management and monitoring, the P333T offers sophisticated tools that facilitate easy configuration and monitoring. These tools assist network administrators in maintaining optimal performance and troubleshooting any issues that may arise. This user-friendly management interface allows for efficient operation and helps reduce downtime, which is crucial in maintaining service quality.

Security is also a critical aspect of the P333T architecture. It includes features designed to protect against unauthorized access and ensure data integrity. This emphasis on security is particularly relevant for organizations handling sensitive information or operating in regulated industries.

Overall, the Lucent Technologies P333T represents a well-engineered solution that combines flexibility, performance, and security. With its range of features and technologies, it empowers organizations to meet their current networking needs while being prepared for future advancements. Its reliability, scalability, and robust capabilities make it a prominent choice for service providers and enterprises alike, solidifying its legacy in the telecommunications landscape.