Specifications

Cajun P330 Switch

Physical

 

Height

2U (88 mm, 3.5”)

Width

482.6 mm (19”)

Depth

450 mm(17.7”)

Weight

7.5 kg (16.5 lb)

Power Requirements AC

 

Input voltage

85 to 265 VAC, 50/60 Hz

Power dissipation

100 W max

Input current

1.3 A@100 VAC

 

0.65 A@200VAC

Inrush current

25 A@100 VAC (max.)

 

50 A@200VAC (max.)

Power Requirements DC

 

Input voltage

-32 to -72 VDC

Power dissipation

100 W max

Input current

3.4 A max

Inrush current

50 A max

Cajun P333T User’s Guide

61

Image 71
Contents Cajun P333T Page Contents Cajun P333T User’s Guide Mtbf Mtbf Cajun P333T LEDs List of FiguresList of Figures Cajun P333T User’s Guide List of Tables List of Tables Viii Cajun P333T User’s Guide Overview Cajun P330 Family FeaturesVLANs Layer 2 FeaturesAuto-Negotiation Congestion ControlCajun P330 Standards Supported CajunView Cajun P330 Network ManagementDurability Cajun P330 ManagerPort Mirroring Cajun P330 Network MonitoringRmon MIBs RFC Smon MIBs RFCChapter Overview Cajun P333T User’s Guide Cajun P333T Front Panel Cajun P333T Front and Rear PanelsPWR FDX Cajun P333T AC and DC Back Panels Cajun P333T Back PanelApplication ApplicationsCajun P330 stacks with a Cajun 330 backbone Positioning Installation and SetupInstalling Stacking Sub-modules Installing the Stacking Sub-module in the Cajun P330Cajun P333T Rack Mounting Rack MountingTo connect stacked switches Connecting Stacked SwitchesIncorrect Stack Connection Removing an Existing Expansion Sub-module Installing Expansion Sub-modulesInstalling the Expansion Sub-module into the Cajun P330 Powering On Cajun P330 Module DC Powering On Cajun P330 Module ACCajun P330 Default Settings Configuring the SwitchCabling 1000BASE-SLX Connecting to the Serial PortAssigning Cajun P330’s IP Stack Address Conventions Used Cajun Campus CLI Command Line InterfaceEstablishing a Serial Connection for Configuration For example telnet Establishing a Telnet SessionRunning the CLI Entering the Supervisor Level Security LevelsEntering the User Level Entering the Privileged LevelTree command General CommandsTop and Up commands Retstatus commandGetting Help Command SyntaxCommand Abbreviations Navigation, Cursor Movement and ShortcutsHow Commands are Organized Commands, Parameters and Default SettingsCommand Hierarchy Cajun Campus CLI Command Line Interface Flowcontrol Trunk Vlan Show timezone command User Level CommandsShow time command Show timeout commandShow image version command Show ntp commandShow system command Show snmp command Show port command Show interface commandField Description Show module commandShow module command Console show flowcontrol Show flowcontrol commandField Show cam commandShow trunk command Show spantree command Addr Show log commandShow download status command Set enablepass command Privileged Level CommandsDisable command Set commandsSet ip route command Set logout commandSet ntp server command Set snmp community read-onlyread Set snmp community commandSet snmp trap rcvraddr Set snmp trap commandSet system name string Set system location commandSet system name command Set system location stringSet system contact string Set system contact commandSet interface command Set port level commandSet port enable command Set port negotiation commandSet port duplex command Set port disable commandSet port speed command Set Vlan command Set flowcontrol command Set trunk command Set spantree priority command Set spantree enable commandSet spantree disable command Clear Commands Set Smon License CommandSync time command Get time commandClear cam command Clear snmp trap commandClear Vlan command Reset command Download commandTo reset module Set defpass command Supervisor Level CommandsSet super password command Power Requirements DC SpecificationsCajun P330 Switch Power Requirements ACEMC Emissions Safety ACSafety DC EnvironmentalStandards Compliance Laser SafetyStacking Sub-module Expansion Sub-modulesLaser Data Laser ClassificationUsage Restriction Ethernet/Fast Ethernet Expansion Sub-module Fast Ethernet Fiber Expansion Sub-modulePower Requirements Backup Power Supply BupsSafety Mtbf System Requirements InstallationCajun P330 Standalone Manager Software Download Documentation and Online Help+972 3 645 How to Contact UsCajun P333T User’s Guide
Related manuals
Manual 12 pages 58.95 Kb

P333T specifications

Lucent Technologies P333T is a highly regarded networking device that has made significant contributions to the telecommunications field. Primarily designed for service providers and large organizations, it is recognized for its robust architecture, which is tailored to handle high-capacity data processing and seamless voice integration.

One of the standout features of the P333T is its support for multiple types of network interfaces, including Ethernet and ATM. This versatility allows organizations to integrate the device into various types of network environments, thereby ensuring compatibility with existing infrastructure. Additionally, the P333T supports both IP and legacy protocols, making it suitable for a wide range of applications and use cases.

The P333T is equipped with advanced packet processing capabilities, enabling efficient data handling and routing. This is particularly important in today's data-driven world, where fast and reliable connections are paramount. The multi-service capabilities of the P333T allow it to effectively manage voice, video, and data traffic simultaneously, thus optimizing the overall performance of the network.

Another significant attribute of the P333T is its modular design. This feature enables organizations to easily upgrade or replace components according to their evolving needs. The ability to scale up as required is essential for businesses looking to future-proof their investments and ensure longevity in their network solutions.

In terms of management and monitoring, the P333T offers sophisticated tools that facilitate easy configuration and monitoring. These tools assist network administrators in maintaining optimal performance and troubleshooting any issues that may arise. This user-friendly management interface allows for efficient operation and helps reduce downtime, which is crucial in maintaining service quality.

Security is also a critical aspect of the P333T architecture. It includes features designed to protect against unauthorized access and ensure data integrity. This emphasis on security is particularly relevant for organizations handling sensitive information or operating in regulated industries.

Overall, the Lucent Technologies P333T represents a well-engineered solution that combines flexibility, performance, and security. With its range of features and technologies, it empowers organizations to meet their current networking needs while being prepared for future advancements. Its reliability, scalability, and robust capabilities make it a prominent choice for service providers and enterprises alike, solidifying its legacy in the telecommunications landscape.