Liebert SmartSwitchTM SmartSwitch Ratings, Connector Receptacle Voltage No. of Conductors

Page 8

Table 1

SmartSwitch™ Ratings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector

Receptacle

Voltage

No. of Conductors

OPD*

Enclosure

Designation

Phase

Neutral

Gnd

Poles

Amps

Type

Refer to

IBMA

 

3743

208

2

1

2

20

R

Figure 2

IBMB

 

3744

208

3

1

3

15

U

Figure 3

IBMC

 

3753

208

2

1

2

30

U

Figure 3

IBMD

 

3754

208

3

1

3

30

U

Figure 3

IBME

 

7324

208

3

1

3

60

U

Figure 3

420R9V

 

420R9V

208

3

1

3

20

U

Figure 3

460R9V

 

460R9V

208

3

1

3

60

U

Figure 3

515R2

 

5262

120

1

1

1

1

15

U

Figure 3

515R4

 

(2) 5262

120

1

1

1

1

15

R

Figure 2

520R2

 

5362

120

1

1

1

1

20

R

Figure 2

520R4

 

(2) 5362

120

1

1

1

1

20

R

Figure 2

530R1

 

9308

120

1

1

1

1

30

U

Figure 3

615R2

 

5662

208

2

1

2

15

R

Figure 2

620R2

 

5462

208

2

1

2

20

R

Figure 2

630R1

 

9330

208

2

1

2

30

U

Figure 3

1420R1

 

8410

120/208

2

1

1

2

20

U

Figure 3

1430R1

 

9430

120/208

2

1

1

2

30

U

Figure 3

1520R1

 

8420

208

3

1

3

20

U

Figure 3

L515R1

 

4710

120

1

1

1

1

15

R

Figure 2

L520R1

 

2310

120

1

1

1

1

20

R

Figure 2

L530R1

 

2610

120

1

1

1

1

30

U

Figure 3

L615R1

 

4560

208

2

1

2

15

R

Figure 2

L620R1

 

2320

208

2

1

2

20

R

Figure 2

L630R1

 

2620

208

2

1

2

30

U

Figure 3

L1420R1

 

2410

120/208

2

1

1

2

20

U

Figure 3

L1430R1

 

2710

120/208

2

1

1

2

30

U

Figure 3

L1520R1

 

2420

208

3

1

3

20

U

Figure 3

L1530R1

 

2720

208

3

1

3

30

U

Figure 3

L2120R1

 

2510

120/208

3

1

1

3

20

U

Figure 3

L2130R1

 

2810

120/208

3

1

1

3

30

U

Figure 3

FW120

 

None

120

1

1

1

1

20

R

Figure 2

FW130

 

None

120

1

1

1

1

30

U

Figure 3

FW220

 

None

208

2

1

2

20

R

Figure 2

FW230

 

None

208

2

1

2

30

U

Figure 3

FW230N

 

None

208/120

2

1

1

2

30

U

Figure 3

FW330

 

None

208

3

1

3

30

U

Figure 3

FW330N

 

None

208/120

3

1

1

3

30

U

Figure 3

FW360

 

None

208

3

1

3

60

U

Figure 3

FW113

 

None

230

1

1

1

1

13

R

Figure 2

FW325N

 

None

400/230

3

1

1

3

25

U

Figure 3

FW350

 

None

400

3

1

3

50

U

Figure 3

Consult Factory for other available connectors not shown.

* OPD - Maximum size of Overcurrent Protection Device (fuse or circuit breaker) supplying SmartSwitch.

4 Introduction

Image 8
Contents SmartSwitch Power ProtectionPage Table of Contents Figures Important Safety Instructions Specifications IntroductionElectrical Specifications SmartSwitch Ratings Connector Receptacle Voltage No. of ConductorsDesignation Phase Neutral Gnd Poles Amps Type Refer to EnclosureUnpacking and Installation Location ConsiderationsLb.-in N-m Input and Output Power ConnectionsWire Size Tightening Torque 17.25 18.5 469 Typical 25 to 60 Amp SmartSwitch Underfloor / Wallmount Unit Typical Input and Output Power Connections Control Wiring Connections GroundingDescription of SmartSwitch Operation Status IndicatorsSmartSwitch Status Indicators Indicator DescriptionExample View Status Response RS-232 Ascii Communication Port Customer CommandsRS-232 Communications Port Logged Events include Example View Settings ResponseExample View Event Log Response Bypass/Transfer Control Switch Operator ControlsOperating Guidelines Operating Guidelines Maintenance Maintenance Automatic Transfer Switch Technical Support