Liebert 700-3000 VA user manual Weight kg lbs

Page 25

SPECIFICATIONS

MODEL NUMBER

GXT1500RT-120

 

GXT2000RT-120

 

 

GXT3000RT-120

MODEL RATING

1500 / 1050

2000 / 1400

 

 

3000 / 2100

VA/W

 

 

 

 

 

 

DIMENSIONS: in (mm)

 

 

 

 

 

 

Unit

7.0 x 19.3 x 16.9

 

7.0 x 19.3 x 16.9

 

 

7.0 x 19.3 x 16.9

W x D x H

(177 x 522 x 430)

 

(177 x 522 x 430)

 

 

(177 x 522 x 430)

Shipping

13.38 x 26.0 x

 

13.38 x 26.0 x 22.25

 

 

13.38 x 26.0 x

W x D x H

22.25

 

(340 x 660 x 565)

 

 

22.25

 

(340 x 660 x 565)

 

 

 

 

(340 x 660 x 565)

WEIGHT: kg (lbs)

 

 

 

 

 

 

Unit

60.9 (27.7)

80.9 (36.8)

 

 

85.9 (39.0)

Shipping

68.0 (30.9)

88.0 (40.0)

 

 

93.0 (42.3)

INPUT AC PARAMETERS

 

 

 

 

 

 

Voltage Range (typical)

120 VAC nominal; variable based upon output load

100% - 90% Loading

90-93 VAC to 134-138 VAC

 

90% - 70% Loading

80-83 VAC to 134-138 VAC

 

70% - 30% Loading

70-73 VAC to 134-138 VAC

 

30% - 0% Loading

60-63 VAC to 134-138 VAC

 

Frequency

48.1 - 51.9 Hz or 57.6 - 62.4 Hz; auto sensing

Input Power Cord

6 ft. detached, w/

 

6 ft. detached, w/

 

6 ft. detached, w/

 

NEMA 5-15 plug

 

NEMA 5-20 plug

 

NEMA L5-30 plug

OUTPUT AC PARAMETERS

 

 

 

 

 

 

Output Receptacles

(8) NEMA 5-15R

 

(6) NEMA 5-15R

 

(6) NEMA 5-15R

 

 

 

(2) NEMA 5-20R

 

(1) NEMA L5-30R

Voltage

100/110/120/127 (switch selectable) VAC; ±3%

Frequency

 

 

50 Hz or 60Hz

 

Waveform

 

 

Sinewave

 

Main Mode Overload

200% for 8 cycles; 130% for 10 seconds with transfer to bypass

BATTERY PARAMETERS

 

 

 

 

 

 

Type

Valve-regulated, nonspillable, lead acid

Qty. x Voltage x Rating

4 x 12V x7 or 7.2 AH

 

8 x 12V x 6.5 or 7.0

 

8 x 12V x 7 or 7.2

 

 

 

AH

 

AH

Batt. Mfg./ Part #

CSB GP1270F2 or Panasonic LC-R127R2CH1

Back-up Time

See Typical Battery Discharge Curves

Recharge Time

5 Hours to 95% capacity after full discharge into 100% load

ENVIROMENTAL

 

 

 

 

 

 

Operating Temperature

+32° F to +104° F (0° C to +40° C)

Storage Temperature

+5° F to +122 °F (-15° C to +50° C)

Relative Humidity

0% to 95%, non-condensing

 

Operating Elevation

Up to 10,000 ft. (3000 m) at 40° C without derating

Storage Elevation

50,000 ft. (15.000 m) maximum

Audible Noise

 

 

<50 dBA, at 1 meter

 

AGENCY

 

 

 

 

 

 

Safety

 

 

UL 1778, c-UL Listed

 

RFI/EMI

FCC Part 15, Subpart B, Class A

Immunity

 

 

IEEE 587 Category A

 

25

DISCONTINUED

PRODUCT

Image 25
Contents UPStation GXT Important Safety Instructions Introduction and System Description Battery Charger RECTIFIER/POWER Factor Correction PFC CircuitMajor Components InverterDC to DC Converter BatteryDynamic Bypass MINI-TOWER/TOWER UPS Installations General InstallationRACK-MOUNT UPS Conversion and Installation RACK-MOUNT Conversion DiagramsOptional Battery Cabinets Installation Battery Cabinet Installation DiagramSerial Communications Ferrite Bead InstallationUpstation GXT On/Alarm Silence/Manual Battery Test Button Controls and IndicatorsOperation Normal Mode OperationBattery Recharge Mode Battery Mode OperationUPS Monitoring Communications Interface PortPIN Assignmentcollector to Emiter UPS Intelligent Communications MaintenanceUPS Intellislot Communications For 700/1000 VA MINI-TOWER Models Battery Replacement ProceduresRACK/TOWER Models For 1000 to 3000 VA RACK/TOWER Models Tower Models onlyRack / Tower Battery Replacement Internal Battery minutes Upstation GXT Battery RUN TimesAudible Alarm Conditions Fuse Replacement ProceduresTroubleshooting Problem Cause Solution Troubleshooting GuideVA/W SpecificationsGXT1000RT-120 GXT1000RTE-120 Weight kg lbs Used w/ UPS Model Battery Cabinet SpecificationsLimited Warranty 700-3000 VA 120