LaCie d2 SCSI Hard Drive | Appendix - SCSI Q & A |
| page 31 |
For example, if you connect an Ultra2 (LVD) Wide hard drive (with a theoretical maximum throughput of 80MB/s and maximum cable length of 12 m) to an Ultra Wide (SE) bus (whose theoretical maximum throughput is 40MB/s and maximum cable length 1.5 m), the Ultra2 hard drive will operate in Ultra Wide mode (at a maximum of 40MB/s, with a maximum cable length of 1.5 m). Therefore, the LVD device will not be used to its full potential.
To add a SE peripheral to an LVD bus and preserve the data throughput and cable length of LVD, you can use a SCSI expander called an LVD to SE converter. This converter divides the SCSI domain into two bus segments – one segment will operate at the LVD data throughput and cable length and the other bus segment will operate at the
What issues are involved when connecting a device using a more recent SCSI protocol (for example Ultra3) to an older host adapter (for example, Ultra2)?
In general, when new SCSI protocols are designed they feature backwards compatibility, meaning that they are compatible with most of the previous protocols. This case is no exception. An Ultra3 drive attached to an Ultra2 host adapter will simply operate in Ultra2 LVD mode, with the reduced transfer rates of Ultra2. If you connect that same Ultra3 drive to an even older host adapter
What is termination?
SCSI passes signals between devices over SCSI cables that act as transmission lines. The transmitting device, the cabling and the receiving device must all be impedance matched in order to accomplish maximum transfer of energy (signals) from end to end. If not, upon encountering a change of impedance, part of the signal will be reflected back to the transmitting device. If those reflected signals arrive at the transmitter after it has switched to the receive mode, it will think the reflected signal is the signal it is looking for. Not recognizing the reflected signals will cause that device to issue a SCSI
Termination (or terminators) is used to provide a better impedance match, reducing these reflections to a minimum. Many
Where should I place the terminator?
On external SCSI peripherals, the terminator must be enabled (internal) or placed (external) on the last device on the bus.
Should I use passive or active terminators?
We recommend that you use active terminators. Passive,