GE ML1600, ML2400 quick start QS.4.1 Assigning an IP address to the Multilin Switch

Page 15

QUICK START GUIDE

Several styles of connector are used to terminate the attached to the end of the fiber cable. The ST and SC connectors shown below, are among the more popular. Ensures that the UR CPU, switch, and cable have compatible connectors.

FIGURE QS–4: Common Fiber Optic Connectors

QS.4.1 Assigning an IP address to the Multilin Switch

DB9 Female to DB9 Female

Cable Pin-out

Pin 2

Pin 2

 

 

Pin 3

Pin 3

 

 

Pin 5

Pin 5

 

 

The easiest way to configure the switch is through the WEB interface. The switch has been shipped with a default IP address of 192.168.1.2 and a subnet mask of 255.255.255.0. Consult your network administrator to determine if the IP address, subnet mask or default gateway needs to be modified. In our example test network the valid rang of IP addresses is from 3.94.247.1 to 3.94.247.254.

The easiest way to assign an IP address and subnet mask is through the switches console serial port. A diagram of the required cable’s pin-out is shown above. Note that both ends of the cable are terminated in a DB9 pin female connector. Pins 5 of this cable are

MULTILINK ML1600/2400 ETHERNET COMMUNICATIONS SWITCH – QUICKSTART GUIDE

QS–11

Image 15
Contents 1601-0220-A2 GE Multilin Incorporated. All rights reserved Table of Contents Table of Contents TOC-II QS-1 Fiber Twisted Pair copper cableRing Architecture QS.1.2 Supported Network TopologiesStar Architecture Mesh ArchitectureUnshielded Twisted Pair cable Ethernet Unshielded Twisted PairMetres max QS-5 RJ45 Connectors Metres max length QS.3.1 Fiber Optic Ethernet Wavelengths of light820nm 1300nm 1550nm QS.3.2 Single and Multi-mode cable Fiber Cable Cross Section and Physical SpecificationsSingle mode fiber Less attenuation per unit distance QS.4 Optical Power Budget Figure QS-4 Common Fiber Optic Connectors QS.4.1 Assigning an IP address to the Multilin SwitchQS-12 QS-13 QS-14 QS-15 QS-16 QS-17 QS.4.2 Assigning a static IP Address to a personnel computer QS-19 QS-20 Addresses now being used Select Run then enter CMD to start the DOS shellQS-22 QS-23 QS-24 Save Relay has switched over to the alternate port Background QS.5 Tagged VLAN’sConfiguring a Vlan within the switch QS.5.1 Configuring Tagged VLANsQS-29 QS-30 Save QS-32 QS-33 QS-34 QS-35 Configure QS-37 QS.5.2 Configuring the Multilink switch for Ring Only Mode QS-39 QS-40 Select the Edit icon From the configuration menu open the Rstp menuThen Save Enable Status Once saved, select OK, then OK again to exit Select the Configuration Rstp RO Mode menu as shown above Then Save Enable status QS-46 Disable LLA On Ports That are in a Ring You have completed the exercise QS.6.2 Selecting the Proper Version QS.6.1 Updating MultiLink FirmwareQS-50 Following procedure describes how to upgrade the firmware QS-52 ML1600/2400# show version QS.6.4 Updating Using the EnerVista Web Interface Software Using FTP Using Tftp QS-57 QS-58