GarrettCom 6K25 Connecting Ethernet Media, Connecting Fiber Optic ST-type, twist-lock, Copper

Page 29

Magnum 6K25 Managed Fiber Switch

Installation and User Guide (04/06)

Switches are typically rack mounted in a wiring closet see Section 3.3.2 below), but because they have rubber feet they can also be installed on a shelf or table top unit. The compact size allows it to be easily placed in an office or lab area, and it can also be either shelf of wall-mounted (see Section 3.3.1 below).

Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 6K25 site. The rugged metal case of the Magnum 6K25 will normally protect it from accidental damage in a lab or workplace setting. Maintain an open view of the front to visually

monitor the status LEDs. Keep an open area around the unit so that cooling can occur from the small fan on the

left side, while the unit is in operation. See figure below.

Figure 3.1: Location of the Magnum 6K25’s cooling fans

3.2Connecting Ethernet Media

The Magnum 6K25 Switches are specifically designed to support all standard Ethernet media types within a single Switch unit. This is accomplished by using a family of different port Modules which can be individually selected and configured per-port. See Section 2.4 for a description of the PMs.

The various media types supported along with the corresponding IEEE

802.3 and 802.3u standards and connector types are as follows:

IEEE Standard

Media Type

Max. Distance

Port Module

Fiber:

mm1 Fiber

 

 

100BASE-FX

220m ( ft) GBIC-SXSC

 

sgl.m2 Fiber

5Km

GBIC-LXSC

100BASE-FX

mm1 Fiber

2.0km (6,562 ft)

6K6-MSC, -MST

 

sgl.m2 Fiber

18.0km (95K ft)

SSC, SSCL

small form factor

mm1 Fiber

2.0km (6,562 ft)

6K8-MTRJ, -MLC

small form factor

sgl.m1 Fiber

15 km

6KP8- SLC

Copper:

 

 

10BASE-T and 100BASE-TX twisted pair

100m (328 ft)

6K8-RJ45

1 mm = multi-mode

2 sgl.m = single-mode

 

3.2.1Connecting Fiber Optic ST-type, “twist-lock”

The following procedure applies to installations using a PM with ST-type fiber

www . GarrettCom . com

22

Image 29
Contents Managed Fiber Switch Trademarks Canadian Emission Contacting GarrettCom, IncIntroduction Table of ContentsRevisions TroubleshootingWww . GarrettCom . com Media Converters, 10Mb and 100Mb series Personal Switches , 10/100MbPersonal Hubs, 10Mb series Performance Technical SpecificationsNetwork Standards and Compliance, hardware Maximum 10 Mbps Ethernet Segment LengthsManagement Console connector Fiber Single-mode connector typesPower Supply Internal DC Power Supply OptionsNebs Testing and Certification Nebs certified Alarm Contact OptionalPer-port MDI or Mdix on RJ-45 Agency ApprovalsOrdering Information 6K PoE Modules with 48VDC Pass-Through For Gigabit module configuration options6K PoE Modules with 48VDC Power Inside Introduction Inspecting the Package and Product Product Description Magnum 6K25 Managed Fiber Switch Magnum 6K25 and 6K25R chassis 1a Regular 6K25 front view, configured for 24 +1 Gb portsEight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiber Eight-Port Copper Module, 6K8-RJ45 The 6K25-Series’s8-port New PoEPower Inside, model PI6KP8-45RJ MDIX, 10/100Mb 8-port ACT LK RX Gigabit 1000Mbps port modules Four-Port 10 Mb mm Fiber ST Modules@ 1000Mb Fiber SC + 4@10/ 100Mb Packet Prioritization, 802.1p QOSFrame Buffering and Flow Control GarrettCom proprietary MIBs for Snmp Managed Network Software MNS-6K for Magnum 6K25-Series„ Features Fiber-Built-In „ Managed switching for high performance Ethernet LANs„ RJ-45 ports are MDI/MDIX supported „ Nebs and Etsi tested and certifiedApplications Example 1 Magnum 6K25 Switch for a Vlan applicationInternet Locating Magnum 6K25 Switches InstallationConnecting Fiber Optic ST-type, twist-lock Connecting Ethernet MediaIeee Standard Media Type Max. Distance Port Module Fiber CopperConnecting Single-Mode Fiber Optic Connecting Fiber Optic SC-type, Snap-InMedia Ieee Standard Media Ieee Standard ConnectorRack-mounting for 19 Retma racks, regular Magnum 6K25s Table-Top or Shelf Mounting2 Reverse Magnum 6K25 units, rack-mounted in a frame Rack-mounting, Reverse version of the Magnum 6K25sPowering the Magnum Managed Fiber Switch Remove Chassis Cover 6K25 Port Module 6KPM InstallationPreparation for Installing and Removing 6KPMs 1a Removing Chassis Cover Installing 6KPM Cards in the Magnum 6K25 Uplink 2f Securely latching up 6KPM Cards into a Magnum 6K25 Firmly. .5.3a Top View 6 retaining s crews shown by arrows Removing 6KPM CardsRemove 6KPM Card Connecting the Console Terminal to Magnum 6K25 ManagementConsole DB-9 Port 1 RS-232 DB-9 Console Com port Serial port pin assignments Pin Signal DescriptionDB-9PinConsole1port connector Address Learning Switching FunctionalityFiltering and Forwarding Up-link MDI-MDIX on RJ-45 port modules, for port 1 only Status LEDsAuto-CrossMDIX and Auto-negotiation, for RJ-45 ports PWRWww . GarrettCom . com Flow-control, Ieee 802.3x standard ’cvr 6KP46KPM Module Description Introduction Magnum 6K25 Managed Fiber Switch Port ModulesSegments. When installed in a Mode ST-type connectorsSwitch, the copper port Dual speed copper ports.6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module Mode SC-type connectors. It Provides an advantage Mode 100Mbps fiber opticFiber functions in one Module of the 6K25 Switch Transceivers all in one module. ThisWww . GarrettCom . com Link Port@ 100Mbps Multi-Mode Fiber portActivity FULL/HALF Module is a combo module with Magnum 6KP8-45MTCopper and fiber Small Form Factor Placing more ports on one module6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port PoE LEDs Summary Fig. the top 8-RJ45 6KP8-45-2SLC 14 6KM-BLNK GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC ConnectorBefore Calling for Assistance No Problem Found When Calling for AssistanceReturn Material Authorization RMA Procedure B1.0 Specifications for Magnum 6K25 SWITCHES, DC Power Appendix B Internal DC Power Supply OptionsPower Supply Internal -48VDC Option Shipping and Packaging InformationB3.0 Applications for DC Powered Switches Magnum 6K25s. see figure at right B4.0 InstallationB4.1 UL Requirements for DC-powered units B6.0 Ordering Information B7.0 TroubleshootingB5.0 Operation GND Appendix C Internal DC Dual-Source Power OptionC5.0 Installation C4.0 Features and Benefits of the DUAL-SOURCE DesignC6.0 Ordering Information C5.1 UL RequirementsExample Magnum 6K25R-48VDC Example Magnum 6K25R-24VDC or Magnum 6K25R-125VDC