APPENDIX C: Internal DC Dual-Source Power Option
C1.0 SPECIFICATIONS - FOR MAGNUM 6K25 FIBER SWITCH Power Supply (Internal,
DC Power Connector: First Source: “A+”,
GND: | Terminal for “earth” or ground wire connection to the hub chassis |
Input: | Two separate sources, each at 36 - 70 VDC |
Power Supply (Internal, 24VDC | |
DC Power Connector: First Source: “A+”, | |
GND: | Terminal for “earth” or ground wire connection to the hub chassis |
Input: | Two separate sources, each at 20 - 36 VDC |
Power Supply (Internal, 125VDC | |
DC Power Connector: First Source: “A+”, | |
GND: | Terminal for “earth” or ground wire connection to the hub chassis |
Input: | Two separate sources, each at 88 - 150 VDC |
With the exception of the dual DC input power connections and the power supply, all specifications and configuration options for the Magnum 6K25
C2.0 MAGNUM 6K25, with
The functionality of the Magnum 6K25 Switch
C3.0
option is designed using diodes inside of the chassis on each DC power input line. A diode is placed in each of the four input lines (behind the four
external power connection terminals) so that power from an external source
can only flow into the unit. This allows the unit to operate whenever DC power is correctly applied to either or both of the two inputs
www . GarrettCom . com