GE 70R-1000D manual Delayed Transition 1600 to 3000 Amps, Movable E3 Contact Stationary

Page 32

Power Panel and Replacement Parts (cont’d)

Delayed Transition - 1600 to 3000 Amps

NN

EN

CN/

CNO

CE/

CEO

N1

N2

E1

E2

ARC GRID

N3 ASSEMBLY

SCR-N

SCR-NO

SCR-EO

SCR-E

MOVABLE

E3 CONTACT

STATIONARY

CONTACT

 

 

 

 

 

 

 

 

 

 

 

 

 

Tag

Description

 

 

Recommended

 

Stock Numbers by Amperage

 

 

 

 

 

as Spares

1600

 

2000

 

3000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N1,2,3

 

 

 

 

 

 

S-1126F(2)

 

 

 

E1,2,3

 

 

 

 

 

 

 

 

 

Cable Connection Lug, CU Wire

 

 

 

 

Optional

 

 

 

T1,2,3

 

 

 

 

 

 

 

 

 

 

 

 

 

(8) 600MCM-2

 

 

 

NLN,ELN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stationary Contact Assembly Kit

 

 

23P-4134X

 

23P-4134Y

 

23P-4134Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Arc Grid Assembly Kit

 

 

23P-1171

 

23P-1171

 

23P-1171

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Movable Contact Assembly Kit

 

 

23P-1400

 

23P-1400

 

23P-1344

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN/CNO

Main Operator Solenoids

 

*

 

 

See Chart Below

 

 

 

CE/CEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCR-N/SCR-E

SCR

 

 

*

 

 

PS-8896

 

 

 

SCR-NO/SCR-EO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage System

 

 

 

 

Solenoid Part No.

 

 

 

Volts

Ph

Wire

Coil VDC

Pole

 

 

 

 

 

 

 

 

 

 

 

 

120

1

2

120

2

S.P.O.

 

S.P.O.

 

S.P.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120/240

1

3

240

2,3

K-2151

 

K-2151

 

K-2151

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240

3

3

240

3

K-2151

 

K-2151

 

K-2151

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120/208

3

4

208

3,4

K-2151

 

K-2151

 

K-2151

 

 

 

 

 

 

 

 

 

 

 

 

 

 

480

3

3

480

3

K-2160

 

K-2160

 

K-2160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575

3

3

575/600

3

S.P.O.

 

S.P.O.

 

S.P.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

277/480

3

4

480

3,4

K-2160

 

K-2160

 

K-2160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120/240

2

4

240

4

K-2151

 

K-2151

 

K-2151

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240/416

3

4

416

3

 

 

Consult Factory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Coil Hardware Kit

 

 

 

 

 

 

 

SN/SNO-1,2

 

Switch Bracket Assembly

 

23P-1540

 

23P-1540

 

23P-1540

 

 

 

 

 

 

 

 

 

 

 

 

 

SE/SEO-1,2

 

Switch Bracket Assembly

 

23P-1541

 

23P-1541

 

23P-1541

 

 

 

 

 

 

 

 

 

 

 

 

 

SN/SNO-3,4

 

Switch Bracket Assembly

 

23P-1542

 

23P-1542

 

23P-1542

 

 

 

 

 

 

 

 

 

 

 

 

 

SE/SEO-3,4

 

Switch Bracket Assembly

 

23P-1543

 

23P-1543

 

23P-1543

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

ZTG/ZTGD Operation and Maintenance Manual (70R-1000D)

GE Zenith Controls

Image 32
Contents GE Zenith Controls Introduction Authorized ServiceTable of Contents Safety / Installation Equipment Inspection and StorageFinal Equipment Inspection MountingEngine Start Control Connections Installation cont’dPower Connections Installation cont’d GE Zenith Controls Initial EnergizationInitial Energization cont’d R E T E S TMX150 Microprocessor Controller MX150 ControllerMX150 Microprocessor Controller cont’d LCD & KeypadUser Setting for Voltage & Frequency Standard Features, Mstdg Option PkgSource CalibrateS13 Std. Features, Mstdg Option Pkg. cont’dR50 Standard Features, Mexeg Option Pkg CDP replaces CDTOptional Accessories How to Set the System Clock CDT One Event Timer ExerciserCDT One Event Timer Exerciser cont’d How to Bypass Cancel an exercise during an exercise cycleCDP Clock Exerciser Load / No-Load Clock ExerciserMX150 User Setup CFG Menu Turn options on or OFF via keypad through the CFG menuMX150 User Setup SET Menu Change adjustable values through the SET menuMX150 User Setup System Info View System DataTesting ATS TestingDelayed Transition Standard TransitionTimer Designations as they appear in the SET menu Sequence of OperationControls Power Supply CPS Standard and Delay TransitionDelayed Transition CPS Schematic Controls Power Supply CPS cont’dStandard Transition CPS Schematic Troubleshooting and Diagnostics General TroubleshootingMaintenance and Testing Inspection and CleaningTesting ServicingPower Panel and Replacement Parts Standard Transition 40 to 260 Amps Solenoid TypePower Panel and Replacement Parts cont’d Standard Transition 400 to 600 Amps Molded TypeStandard Transition 800 to 1200 Amps ARC Grid Removed for ClarityStandard Transition 1600 to 3000 Amps Stationary Contact Moveable ContactDelayed Transition 40 to 600 Amps AmpsDelayed Transition 800 to 1200 Amps SCR-EO Movable Contact Stationary ContactDelayed Transition 1600 to 3000 Amps Movable E3 Contact StationaryPage Page Page GE Zenith Controls