GE PB3-POS-RP user manual Detailed Installation Steps

Page 16

16

PB3-POS-RP ProBridge User Manual

Switch Settings as shown above are:

Camera Number 1 (SW1 5-8)

Generic Printer (SW3 1-8)

PB3 Termination OFF (SW4 3)

Detailed Installation Steps

Note: Modify the DVMRe’s default baud rate of 19200 to 57600.

1)At the minimum set or verify the DIP Switch settings for the Camera Number, PB3 Termination, and the type of serial device.

2)Disconnect the existing serial device cable from the Printer and install the ECR Interconnect Cable (multiple DB25 connectors) to the serial device as shown on page 14.

Note: If the existing connection is using a DB9 to DB9 connection, then use the supplied Triport cable in place of the ECR Interconnect cable. See the Triport cable specification on page 45.

3)Reconnect the serial device Cable to one of the DB25F connectors on the ECR Interconnect Cable as shown on page 14.

4)Connect the PB3 Interface Cable (DB25M to DB9F) to the remaining DB25F connector on the ECR Interconnect Cable as shown on page 14. Connect the other end (DB9F) to the DB9M connector on the PB3 unit (Port 2).

5)Connect the PB3 Power Supply to the unit, but do not plug in the power.

Note: If only one (1) PB3 unit (one cash register) is to be connected, skip to Step 9 below.

Image 16
Contents PB3-POS-RP ProBridge Page Efore Y OU B Egin Ntroduction DIP Switch Settings Before You Begin Customer SupportGE Security Conventions Used in this ManualPB3-POS-RP ProBridge Introduction PB3-POS-RP OverviewCompatibility Additional EquipmentDisclaimer DVMRe Type Software VersionPB3-POS-RP Box Contents PB3 System ComponentsInstallation Environment PB3-POS-RP ProBridge includesPower 4310-0008 220VAC Power Supply Power Supply Input Installation PB3 ComponentsTypical System Layout Monitor DVMRe TriplexRequired Dip Switch Information Default Factory Dipswitch SettingsDetailed Installation Steps Verify Operation PB3-POS-RP ProBridge Dip Switch Settings SW1 SettingsSW1 -Switches Display ModeReset Clear Memory Demo Mode Simulated MessageAuto Line Feed SW1 Switches SW2 Switch SW2 SettingsSW2 Switches Protocol SW3 Switches SW3 SettingsIncluded Interfaces SW3 SW4 Settings SW4 Switches 1,2SW4 Switch SW4 SwitchesProblem Probable Cause TroubleshootingSolution Setup Hyperterminal SetupEquipment Required Laptop connected to PB3 running HyperTerminal PB3-POS-RP ProBridge Enter Main Menu Option 2 Port #2 Menu Selection 5 Mode Menu Selection 2 Protocol OptionsMenu Selection 3 Baud Rate Menu Selection 4 ParityMenu Selection 6 Code Character Menus Selection 7 Device TypeMain Menu Option 3 Text Setup Compare Use this command to enable or disable Text filteringText String Bypass CountAppend Line Feed Example of setting Text Setup Menu options Receipt Main Menu Option 4 Alarm Setup Main Menu Option 4 BackupPB3 Specifications Cable Specifications ProBridge to Triplex DVMRe-CTProBridge to DVMRe DVMRe-CD/S DB9FRJ-45 Connector ProBridge to ProBridge CableProBridge to Printer Interconnect Cable ProBridge Interconnect Cable to serial device Part Number 4310-0068A Communication Type RS232Triport Cable Hardware Handshake Jumpers JP1 and JP2Triport Cable Modifications Contacting technical support Online publication library