6)If more than one cash register interface is to be installed repeat steps
7)Connect each PB3 unit together by using an RS485 cable with
Note: The installer shall provide this cable.
8)Confirm that each PB3 has the proper termination setting.
9)Connect the PB3 closest to the DVMRe using the supplied cable from Port 1 (RJ45 outer receptacle) of the PB3 to the RS232/2 port on the DVMRe unit.
Note: Modify the DVMRe’s default baud rate of 19200 to 57600.
10)Supply power to the PB3.
Verify Operation
To verify proper operation process several transactions at the Cash Register.
To verify proper operation with a
Select
The text box will display any transaction data as it is passed to the PB3 unit from the POS device. Be aware that some POS devices only send transaction data until the end of the transaction (when the receipt is printed).