GE GFK-0726B manual Serial Port Setup, ECLiPSor OnTOP Options, Programmable Setup Options

Page 20

4

Serial Port Setup

There are several serial port configuration options. Some of these options are set using

ECLiPS or OnTOP, and others can only be set by an executing State Logic program.

ECLiPSor OnTOP Options

The options available in the ECLiPS or OnTOP menus to change the configuration of the SLP serial ports are displayed below.

The options available in the ECLiPS or OnTOP menus to change the configuration of the SLP serial ports are displayed below.

Change Programming Port

Enable/Disable CCM Port

Set CCM Station Number

Set the RS￿422/485 Status of each Port

Serial Options Set by ECLiPS or OnTOP

Each of these options is set in the State Engine Configuration Menu selected from the

Debug Mode Project Menu in ECLiPS or from the Controller Option in OnTOP.

Programmable Setup Options

On power up the serial port parameters are set to their default settings. These settings may be changed by using the Set_Commport programming keyword in the control pro- gram. The Set_Commport keyword and parameters must be executed by the control program to change the serial port settings. Just changing the parameters in the ECLiPS serial communications setup form does not automatically change these settings.

After the SLP serial port parameters are set, ECLiPS automatically enters the Set_Comm- port instruction into the program when the following selections are made. Select the LIST option from the program mode menu; then select the Communication Ports option. Highlight the appropriate port and press <Enter>. ECLiPS prompts whether to enter the port name only or enter reconfiguration data. After selecting Enter Reconfiguration Data, the Set_Commport keyword plus the instructions to change the serial port param- eters are entered into the ECLiPS program.

These options affect the SLP serial port configuration only, not the ECLiPS or OnTOP serial port setup. The option to change the ECLiPS or OnTOP host computer serial port configuration is available only when there is some problem connecting ECLiPS or On- TOP to the SLP. The only options which can be changed on the ECLiPS or OnTOP serial port configuration are selecting COM1 or COM2 and changing the baud rate.

GFK-0726B

Chapter 4 Serial Communications

4-3

Image 20
Contents GE Fanuc Automation GFL±002 GE Fanuc Automation North America, Inc Page Content of this Manual We Welcome Your Comments and SuggestionsContents SampleLogicmasterConfigurationScreen Contents Chapter State Logic Processor Description Physical Description GFK-0726BSeries 90-30 State Logic Processor Operational Description Inserting the SLP Chapter Installation and MaintenanceSelecting the Right Slot Configuration Sample Logicmaster Configuration ScreenBattery Status LED is not on Steady Chapter TroubleshootingSerial Communication Problems Communications Problems with ECLiPS or OnTOP Communications Problems with Another Serial DeviceChapter SerialCommunications Programming Serial Communications ECLiPSor OnTOP Options Serial Port SetupProgrammable Setup Options Serial Port Parameters Serial Cable Mini Converter KitOther Cable Options RTS CTS DTR GND PCMNo Connection Signal Ground Custom Made CablesWYE Cable Connections for Series 90-30 SLP Chapter Specifications HardwareSpecificationsSLP I/O and Register Specifications Firmware Specifications