Gefen EXT-DP-441 manual Telnet Control, Gefen

Page 27

TELNET CONTROL

The Gefen 4x1 DisplayPort Switcher supports Telnet for controlling the Switcher over a network. To access this feature, an IP address, subnet, gateway, and port numbers need to be set correctly. Consult the network administrator to obtain the proper IP address and settings for this product to properly communicate with the Switcher over a network.

The Telnet control must be configured using RS-232 commands. Once properly configured, enter the IP address that was assigned to the Switcher using a terminal program or other Telnet client.

1.Connect the Switcher to a computer using RS-232.

2.Use a terminal emulation program (e.g. HyperTerminal, PuTTY, Indigo, etc.) to connect to the Switcher. See page 14 for information on RS-232 configuration.

IMPORTANT: When using HyperTerminal under Windows XP, the LF (line feed) character option must be enabled.

3.Apply power to the Switcher. Information similar to the following will be displayed in the terminal window:

===================================================

GEFEN

DISPLAY PORT 441 FW version: 1.3

===================================================

4.Use the #ipconfig command to display the current IP settings. The factory (default) settings are displayed below:

#ipconfig

 

-------------------

TCP/IP settings ---------------

MAC addr

= 00:1C:91:02:40:00

IP addr

= 192.168.0.70

Net Mask

= 255.255.255.0

Gateway

= 192.168.0.1

Web Server Port

= 80

Telnet Server Port

= 23

Telnet password on login is set to ON

Note that the Telnet password is set to ON. A user name and password can be set for additional security. This option can also be disabled. See page 20 for details.

24

Image 27
Contents Page Write To Asking for AssistanceTechnical Support Technical Support HoursContents How It Works Gefen 4x1 DisplayPort SwitcherIntroduction GefenOperation Notes Features FeaturesPackage Includes Front Panel Front Panel LayoutFront Panel Descriptions Input Indicators 1Back Panel Back Panel LayoutDP Out Back Panel DescriptionsLayout and Description IR Remote Control UnitInstalling the RMT-4IR Battery Corresponding DIP Switch Settings for each IR Channel How to Resolve IR Code ConflictsConnecting the 4X1 Displayport Switcher How to Connect the 4x1 DisplayPort SwitcherWiring Diagram for the 4x1 DisplayPort Switcher Switching sources using the IR Remote Control Operating the 4X1 Displayport SwitcherFront Panel Buttons and LED Indicators Switching sources using the front panel buttonsSwitching sources using Telnet Switching sources using RS-232RS-232 Control Serial Port SettingsRS-232 Commands Command Syntax#GETPASS Command #GETUSERNAME Command #IPCONFIG Command#RSTIP Command #SETHTTPPORT Command #SETPASS Command#SETTELNETPORT Command #SGATEWAY Command #SETUSERNAME Command#SNETMASK Command #SIPADD Command#ACTIVEBOLO Command #USETELNETPASS Command#IRRMTADD Command #FADEFAULT Function#STBYMODE Command #LOCKPOWER CommandRouting and Extender Commands Command DescriptionCommand Gefen Telnet Control#sipadd New IP set to Specifications Product Registration WarrantyThis product uses UL listed power supplies