Foundry Networks M2404C, M2404F manual Example, Application is downloaded into /Boot directory

Page 33

Foundry NetIron M2404C/M2404F Metro Access Switches

1.Copy the device software image file to the appropriate TFTP directory on the workstation.

2.Log into the switch through the console port or through a Telnet session. If you log in using Telnet, your Telnet session will disconnect when you reset the switch to run the new software.

3.Make sure there is enough free space on the device file system. Use “dir” command for this. Free disk space should be at least 0.5MB larger then the downloaded application size.

Example:

device-name#dir

 

 

 

Listing Directory flash:/:

17:56 Boot/

d

S

2048

Jun 30 2005

d

S

2048

Jan

1 1993

00:04 Etc/

d

S

2048

Jun 14 2005

12:01 Java/

d

S

2048

Jan

1 1980

00:00 Log/

d

S

2048

Jul

5 2005

21:36 Usr/

d

SH

2048

Jan

1 1980

00:00 Hidden/

-260 Jan 1 1993 00:00 profile.cfg

-43796 Jul 5 2005 21:26 dflt_startup_bin.cfg

-5382 Jul 5 2005 21:26 dflt_startup.cfg

Free disk space 5655104

4.If there is not enough free space, delete unnecessary files. This is done by using “del” command.

device-name#del<filename>

Example:

device-name#del /Boot/Oldimage.bin

5.Download the device software image from the TFTP server using the copy application command in Privileged (Enable) mode:

device-name#copy application <TFTP URL> [<destination file name>]

Example:

device-name#copy application tftp://192.192.54.10/M2404Cv2.0.bin

NOTE The switch remains operational while the image is downloaded.

The application is downloaded into /Boot directory.

January 2007

© 2007 Foundry Networks, Inc.

27

Image 33
Contents Great America Parkway Santa Clara, CA Page Connected to a power source Safety ConsiderationsLocation Transmitters which may endanger your eyesJanuary Foundry Networks, Inc Iii Table of Contents Appendix a Cautions and Warnings About This Document Who Should Use This GuideHow This Document is Organized Related Publications Conventions Used in this DocumentIntroduction OverviewFront Panel Hardware DescriptionNetIron M2404F Front Panel Main Components NetIron M2404C Front Panel Main ComponentsComponent Description GigE Dual-Mode Ports Unit LEDsLabel Function Indication PSU #1Port Status LEDs NetIron M2404C Port Status LEDsNetIron M2404F Port Status LEDs NetIron M2404F Dual-Mode Port Status LEDs RJ-45 IndicatorsTwo AC Power supplies Rear Panel with AC Power-Supply UnitsPanel Main Components Two grounding postsRear Panel with DC Power-supply Units Power Supply UnitsTwo DC Power supplies Blank Covers Blank Filler for Empty Power-Supply Slot Packing List Installation and SetupUnpacking Rack MountingRack Mounting Specifications Switch Side PC Side DC Power installationEthernet Cables Console InterfaceGrounding the Switch Laser Safety Initial Configuration Initial Configuration Using the ConsoleEnter Ends an input line TabExample Saving Configuration in a Text FileDownloading Configuration from Backup Text File Reloading Factory Defaults ConfigurationMonitoring/Configuring CPU Operating Temperature Configuring Temperature Management Parameters Temperature Management CommandsRestoring the Default Value Viewing the StatusMonitoring the Power Supplies Status Viewing the status during system bootViewing the status during operation Bist Test Results Review Built-In Self Test Bist Startup Execution of Bist Device-name Preparing to Download an Image Using Tftp Downloading a Software Image to the Switch UsingDownloading a Device Software Image Using Tftp Software DownloadApplication is downloaded into /Boot directory Example with reload command Downloading a NI-M2404WebView Image Using TftpJava image is downloaded into /Java directory Software Upgrade via Ethernet Port OutbandHot-swapping a Power Supply Panel with the two screwsCorresponding PSU LEDs on the front panel Physical Specifications SpecificationsDimensions Operating ConditionsManagement Features Safety and Electromagnetic CompatibilitySafety Vcci Japan Class a Appendix a Cautions and Warnings Foundry NetIron M2404C/M2404F Metro Access Switches Achtung Grounding Advertencia Conexión a Tierra Advertencia Cableado Para Enchufe DE Corriente Nacional Foundry NetIron M2404C/M2404F Metro Access Switches