Foundry Networks M2404F, M2404C manual Achtung

Page 42

Foundry NetIron M2404C/M2404F Metro Access Switches

Warning Statements

A warning calls your attention to a possible hazard that can cause injury or death. The following are the warnings used in this manual.

"Achtung" weist auf eine mögliche Gefährdung hin, die zu Verletzungen oder Tod führen können. Sie finden die folgenden Warnhinweise in diesem Handbuch:

Un avertissement attire votre attention sur un risque possible de blessure ou de décès. Ci- dessous, vous trouverez les avertissements utilisés dans ce manuel.

Una advertencia le llama la atención sobre cualquier posible peligro que pueda ocasionar daños personales o la muerte. A continuación se dan las advertencias utilizadas en este manual.

WARNING:

The procedures in this manual are for qualified service personnel.

ACHTUNG:

Die Verfahren in diesem Handbuch sind nur für qualifiziertes

 

Wartungspersonal gedacht.

AVERTISSEMENT:

Les procédures décrites dans ce manuel doivent être effectuées par le

 

personnel de service qualifié uniquement.

ADVERTENCIA:

Los procedimientos de este manual se han hecho para personal de

 

servicio cualificado.

 

 

WARNING:

For safety reasons, the ESD wrist strap should contain a series 1 meg

 

ohm resistor.

ACHTUNG:

Aus Sicherheitsgründen sollte ein EGB-Armband zum Schutz von

 

elektronischen gefährdeten Bauelementen mit einem 1 Megaohm-

 

Reihenwiderstand ausgestattet sein.

AVERTISSEMENT:

Pour des raisons de sécurité, la dragonne ESD doit contenir une

 

résistance de série 1 méga ohm.

ADVERTENCIA:

Por razones de seguridad, la correa de muñeca ESD deberá contener

 

un resistor en serie de 1 mega ohmio.

 

 

WARNING:

The equipment is designed to be used with Class 1 Laser fiber optic

 

transmitters which may endanger your eyes. Do not look directly into

 

the fiber optic cables or transmitter.

ACHTUNG:

Die Anlage ist für den Betrieb mit Lichtleitersendern der Klasse 1

 

ausgelegt, die Ihre Augen gefährden können. Schauen Sie auf keinen

 

Fall direkt in Lichtleiterkabel oder –sender.

AVERTISSEMENT:

L’équipement est conçu pour être utilisé avec des transmetteurs laser

 

par fibres optiques de classe 1 qui peuvent endommager vos yeux. Ne

 

regardez pas directement le transmetteur ou les câbles en fibres

 

optiques.

ADVERTENCIA:

El equipo está diseñado para utilizarlo con transmisores ópticos de

 

fibra Láser de Clase 1 que pueden ser perjudiciales para los ojos. No

 

mire directamente a los cables o al transmisor ópticos de fibra.

 

 

WARNING:

HIGH VOLTAGE

 

Disconnect the product from the power line before removing the cover.

 

Any adjustment and maintenance of the opened device should be done

 

only while the device is disconnected from its source of power and

January 2007

© 2007 Foundry Networks, Inc.

36

Image 42
Contents Great America Parkway Santa Clara, CA Page Location Safety ConsiderationsConnected to a power source Transmitters which may endanger your eyesJanuary Foundry Networks, Inc Iii Table of Contents Appendix a Cautions and Warnings About This Document Who Should Use This GuideHow This Document is Organized Conventions Used in this Document Related PublicationsOverview IntroductionHardware Description Front PanelNetIron M2404C Front Panel Main Components NetIron M2404F Front Panel Main ComponentsLabel Function Indication Unit LEDsComponent Description GigE Dual-Mode Ports PSU #1Port Status LEDs NetIron M2404C Port Status LEDsNetIron M2404F Port Status LEDs RJ-45 Indicators NetIron M2404F Dual-Mode Port Status LEDsPanel Main Components Rear Panel with AC Power-Supply UnitsTwo AC Power supplies Two grounding postsRear Panel with DC Power-supply Units Power Supply UnitsTwo DC Power supplies Blank Covers Blank Filler for Empty Power-Supply Slot Unpacking Installation and SetupPacking List Rack MountingRack Mounting Specifications Ethernet Cables DC Power installationSwitch Side PC Side Console InterfaceGrounding the Switch Laser Safety Enter Ends an input line Initial Configuration Using the ConsoleInitial Configuration TabSaving Configuration in a Text File ExampleDownloading Configuration from Backup Text File Reloading Factory Defaults ConfigurationMonitoring/Configuring CPU Operating Temperature Restoring the Default Value Temperature Management CommandsConfiguring Temperature Management Parameters Viewing the StatusMonitoring the Power Supplies Status Viewing the status during system bootViewing the status during operation Built-In Self Test Bist Bist Test Results ReviewStartup Execution of Bist Device-name Downloading a Device Software Image Using Tftp Downloading a Software Image to the Switch UsingPreparing to Download an Image Using Tftp Software DownloadApplication is downloaded into /Boot directory Downloading a NI-M2404WebView Image Using Tftp Example with reload commandSoftware Upgrade via Ethernet Port Outband Java image is downloaded into /Java directoryHot-swapping a Power Supply Panel with the two screwsCorresponding PSU LEDs on the front panel Dimensions SpecificationsPhysical Specifications Operating ConditionsManagement Features Safety and Electromagnetic CompatibilitySafety Vcci Japan Class a Appendix a Cautions and Warnings Foundry NetIron M2404C/M2404F Metro Access Switches Achtung Grounding Advertencia Conexión a Tierra Advertencia Cableado Para Enchufe DE Corriente Nacional Foundry NetIron M2404C/M2404F Metro Access Switches

M2404F, M2404C specifications

Foundry Networks, a key player in the networking industry, has developed a range of high-performance Ethernet switches designed to meet the demands of modern data centers and enterprise environments. Among these products, the M2404C and M2404F switches stand out for their robust features and capabilities.

The M2404C is engineered for flexibility and high performance, offering Layer 2 and Layer 3 capabilities. It supports a wide array of routing protocols, including OSPF, BGP, and RIP, making it suitable for various network architectures. The switch provides up to 48 Ethernet ports with a combination of Gigabit and 10 Gigabit interfaces, ensuring it can handle high bandwidth requirements. This modularity allows organizations to scale their networks seamlessly as their needs evolve.

On the other hand, the M2404F focuses on fiber connectivity and is designed with an emphasis on high-speed fiber handling. This switch also supports advanced Layer 3 routing capabilities, but its standout feature is its support for higher-speed interfaces, like 10 Gigabit SFP+ ports. It is ideal for businesses that require efficient long-distance data transmission and reliable network performance.

Both models feature Foundry's innovative Fabric Technology, which enhances throughput and reduces latency. This technology optimizes data flow and improves overall service quality, making these switches suitable for mission-critical applications. Additionally, they boast a comprehensive management system that simplifies network administration. Foundry Networks emphasizes security, incorporating advanced features like Access Control Lists (ACLs), RADIUS, and TACACS+ support to help secure the network infrastructure.

Scalability is another critical aspect of the M2404C and M2404F. These switches allow for stacking, enabling organizations to expand their network without sacrificing performance. Power over Ethernet (PoE) capabilities in the M2404C provide added convenience for powering devices like IP phones and wireless access points.

In summary, Foundry Networks' M2404C and M2404F switches deliver exceptional performance, advanced features, and robust security, making them an excellent choice for organizations seeking to enhance their networking infrastructure. With their modular design and ability to support high-speed connectivity, they are well-suited for a variety of applications, from enterprise environments to data center deployments.