Eizo FlexScan L675 manual Set the Contrast of the screen Use the Contrast adjustment, Auto

Page 25

4. Set the Output signal range (Dynamic Range) of the signal. Æ Use the “Range Adjustment”.p.47)

This controls the level of output signal range to display the whole color gradation (256 colors). Select the “Range Adjustment”in the color menu.

[Auto]

Push the Auto adjustment button on the front panel while displaying the “Range adjustment” menu to automatically adjust the range. The screen blanks for a moment, and adjusts the color range to display the whole color gradation of the current output signal.

Pressing Auto adjustment button while displaying the contrast/brightness adjustment screen (appeared by pressing the control buttons directly) adjusts the range automatically.

5.Set the Contrast of the screen.

Æ Use the “Contrast” adjustment.

This controls the brightness for the each color (red, blue and green) at a same time.

Select “Contrast/Brightness” in the screen menu and adjust by using the right and left buttons.

• Percentage over the 100 % may cause undisplayable color tone.

6.Set the Brightness of the screen.

Æ Use the “Brightness” adjustment.

This controls the brightness for the entire screen. The brightness of the entire screen is controlled by changing the brightness if the backlight.

Select “Contrast/Brightness” in the screen menu and adjust by using the up and down buttons.

Directly pressing the control buttons also adjusts the contrast and brightness. Press the “Enter” button to save and exit the settings after the adjustment.

ENGLISH

4. ADJUSTMENT 25

Image 25
Contents English Safety Symbols Table of Contents ´ Refer all servicing to qualified service personnel Precautions´ Do not dismantle the cabinet or modify the unit ´ Place the unit on a strong, stable surface Keep small objects or liquids away from the unit´ Set the unit in an appropriate location ´ The equipment must be connected to a grounded main outlet ´ Handle the power cord with care´ Use the correct voltage ´ Do not touch a damaged LCD panel directly with bare hands ´ Handle with care when carrying the unit´ Do not block the ventilation slots on the cabinet ´ Periodically clean the area around the plug ´ Use an easily accessible power outlet´ Unplug the unit before cleaning it ´ Do not touch the plug with wet handsSuggestions for Maximizing Comfort Introduction FeaturesPackage Contents Front Controls & ConnectorsRear Cable Connection Before connectingAnalog Input Digital InputAnalog Input Connecting the signal cableDigital Input 16 2. Connecting UP Plug the other end of the power cord into a power outlet Making Adjustments and Settings How to use the ScreenManagerEntering the ScreenManager Exiting the ScreenManagerMain menu Sub menu Reference ScreenManager Adjustments and SettingsUseful Functions Adjustment LockEizo Logo Disappearing function Procedure Off TimerOff timer system Screen Adjustment AdjustmentAdjustment Procedure for Analog Input Push the Auto adjustment button on the front panelHorizontal flickering, blurring or bars appear on the screen Screen position is incorrect Use the Position adjustment Auto Set the Contrast of the screen Use the Contrast adjustmentScreen position is incorrect Use the Resolution adjustmentSet the Contrast of the screen Set the Brightness of the screenDisplaying a low resolutions 28 4. Adjustment Before the Color adjustment Color AdjustmentTo change the flesh color, etc Use the Hue adjustment To change the saturation Use the Saturation adjustmentTo use the PC’s power saving system Vesa Dpms Power-save SetupTo set the power save with ScreenSaver software Eizo Mpms Power saving system32 4. Adjustment Required system environment Connecting to the USB HUBUSB Example of connectionMonitor Connecting Examples Analog x DigitalAnalog x Analog Digital x digitalSelecting the active input Priority input signalAttaching AN ARM Stand Setup Procedure38 7. Attaching AN ARN Stand Problems Points to check with possible solutions TroubleshootingNo picture Following messagesAfterimages appear Too darkScreen has defective Auto adjustment Button does not operatePixels e.g. slightly light Or darkSetup Change after installingFrequency does not PC is hung up. /Cabinet CleaningLCD Panel Vesa DDC 2B SpecificationsBeeper settings Default settingGlossary Color Temperature TemperatureAfterimage ClockPhase Gain AdjustmentRange Adjustment ResolutionAttaching AN ARM Stand IndexUSB 10,31,33,44 Vesa Dpms 19,31,47 Memo Appendix Appendix / Anhang / AnnexeIi Appendix 480 800 525 907 111 356 556 25.422 12.712 31.778 14.267 180 Pin Assignment Pin-Belegung Affectation des Broches Dimensions AbmessungenCongratulations Why do we have environmentally labelled computers?What does labelling involve? Cadmium Environmental requirements Flame retardantsMercury CFCs freonsWarland Drive, Cypress, CA We, the Responsible PartyPhone 562 431