Eizo FlexScan L675 manual Color Adjustment, Before the Color adjustment

Page 29

4-3. Color Adjustment

The “ColorManagement”menu in the ScreenManager enables to change the color of the screen.

Before the Color adjustment

Allow the LCD monitor to stabilize for at least 20 minutes before making color adjustments.

After finishing each adjustment in the custom mode, select “Save” icon to resister the adjustment. Otherwise, the adjustment will be lost.

The adjustment values represent the current level within the specific adjustment only. They are available only as a reference tool. (To create a uniform white or black screen, the percentages for each will probably not be the same.)

In the analog input, perform the “Range Adjustment” (p.25) before making the color adjustments . The gradation pattern like below is recommended for the “Range Adjustment”.

ENGLISH

1. To change the color tone of the white.

Æ Set the “Temperature”.p.46)

The “Temperature” can be set from 4,000 K to 10,000 K , in 500 K increments (including 9,300 K). The default setting is “OFF”.

To resister the adjustment in the custom mode, select the “Save” icon and then push the enter button.

Setting the temperature under 4,000 K or over 10,000 K invalidates the color temperature setting. (The color temperature’s setting turns “OFF”.)

Adjusting the “Gain” (p. 30) invalidates the color temperature setting. (The color temperature’s setting turns “OFF”.)

4. ADJUSTMENT 29

Image 29
Contents English Safety Symbols Table of Contents ´ Do not dismantle the cabinet or modify the unit Precautions´ Refer all servicing to qualified service personnel ´ Set the unit in an appropriate location Keep small objects or liquids away from the unit´ Place the unit on a strong, stable surface ´ Use the correct voltage ´ Handle the power cord with care´ The equipment must be connected to a grounded main outlet ´ Do not block the ventilation slots on the cabinet ´ Handle with care when carrying the unit´ Do not touch a damaged LCD panel directly with bare hands ´ Periodically clean the area around the plug ´ Use an easily accessible power outlet´ Unplug the unit before cleaning it ´ Do not touch the plug with wet handsSuggestions for Maximizing Comfort Introduction FeaturesPackage Contents Front Controls & ConnectorsRear Cable Connection Before connectingAnalog Input Digital InputDigital Input Connecting the signal cableAnalog Input 16 2. Connecting UP Plug the other end of the power cord into a power outlet Making Adjustments and Settings How to use the ScreenManagerEntering the ScreenManager Exiting the ScreenManagerMain menu Sub menu Reference ScreenManager Adjustments and SettingsEizo Logo Disappearing function Adjustment LockUseful Functions Off timer system Off TimerProcedure Screen Adjustment AdjustmentAdjustment Procedure for Analog Input Push the Auto adjustment button on the front panelHorizontal flickering, blurring or bars appear on the screen Screen position is incorrect Use the Position adjustment Auto Set the Contrast of the screen Use the Contrast adjustmentScreen position is incorrect Use the Resolution adjustmentSet the Contrast of the screen Set the Brightness of the screenDisplaying a low resolutions 28 4. Adjustment Before the Color adjustment Color AdjustmentTo change the flesh color, etc Use the Hue adjustment To change the saturation Use the Saturation adjustmentTo use the PC’s power saving system Vesa Dpms Power-save SetupTo set the power save with ScreenSaver software Eizo Mpms Power saving system32 4. Adjustment Required system environment Connecting to the USB HUBUSB Example of connectionMonitor Connecting Examples Analog x DigitalAnalog x Analog Digital x digitalSelecting the active input Priority input signalAttaching AN ARM Stand Setup Procedure38 7. Attaching AN ARN Stand Problems Points to check with possible solutions TroubleshootingNo picture Following messagesAfterimages appear Too darkScreen has defective Auto adjustment Button does not operatePixels e.g. slightly light Or darkSetup Change after installingFrequency does not PC is hung up. /LCD Panel CleaningCabinet Vesa DDC 2B SpecificationsBeeper settings Default settingGlossary Color Temperature TemperatureAfterimage ClockPhase Gain AdjustmentRange Adjustment ResolutionAttaching AN ARM Stand IndexUSB 10,31,33,44 Vesa Dpms 19,31,47 Memo Appendix Appendix / Anhang / AnnexeIi Appendix 480 800 525 907 111 356 556 25.422 12.712 31.778 14.267 180 Pin Assignment Pin-Belegung Affectation des Broches Dimensions AbmessungenWhat does labelling involve? Why do we have environmentally labelled computers?Congratulations Cadmium Environmental requirements Flame retardantsMercury CFCs freonsPhone 562 431 We, the Responsible PartyWarland Drive, Cypress, CA