Using FortiSwitch-5003A and FortiSwitch-5003 boards for backplane communication

FortiGate-5140 hardware procedures

Caution: FortiGate-5000 series and FortiSwitch-5000 series modules must be protected from static discharge and physical shock. Only handle or work with FortiGate-5000 series and FortiSwitch-5000 series modules at a static-free workstation. Always wear a grounded electrostatic discharge (ESD) preventive wrist or ankle strap when handling FortiGate-5000 series or FortiSwitch-5000 series modules.

Caution: Do not operate the FortiGate-5140 chassis with open slots on the front panel or rear panel. For optimum cooling performance and safety, front panel slots must contain a FortiGate-5000 series module or an air baffle slot filler and rear panel slots must either be covered or must contain a rear transition module or slot filler. As well the removable PEM terminal block covers must be installed over the power connectors on the back of the chassis.

See the following documents for information about installing and removing the following

FortiGate-5000 series and FortiSwitch-5000 series modules:

FortiGate-5001A

FortiGate-5001A Security System Guide FortiGate-5005FA2:

FortiGate-5005FA2 Security System Guide FortiGate-5001SX:

FortiGate-5001SX Security System Guide FortiGate-5001FA2:

FortiGate-5001FA2 Security System Guide FortiSwitch-5003A

FortiSwitch-5003A System Guide FortiGate-RTM-XB2

FortiGate-RTM-XB2 System Guide FortiSwitch-5003

FortiSwitch-5003 System Guide

Using FortiSwitch-5003A and FortiSwitch-5003 boards for backplane communication

FortiSwitch-5003A boards installed in a FortiGate-5140 chassis in slot 1 or slot 2 provide fabric backplane switching for all of the FortiGate-5000 series boards installed in chassis slots 3 and above. Fabric backplane switching is most often used for data communication between FortiGate-5000 series boards in a chassis, between chassis, and between the chassis and the network.

FortiSwitch-5003A and 5003 boards installed in a FortiGate-5140 chassis in slot 1 or slot 2 provide base backplane switching for all of the FortiGate-5000 series boards installed in chassis slots 3 and above. Base backplane switching is usually used for HA heartbeat communication between FortiGate-5000 series boards in HA clusters.

For complete information about using the FortiSwitch-5003A and 5003 for backplane communications (including the FortiSwitch-5003A CLI reference), see the FortiSwitch-5003A and 5003 Fabric and Base Backplane Communication Guide.

FortiGate-5140-R Chassis Guide

3001-30000-87705-20090108http://docs.fortinet.com/ Feedback

Image 30
Contents FortiGate-5140-R FortiGate-5140-R Chassis Guide Contents For more information Comments on Fortinet technical documentationFortiGate-5140 chassis FortiGate-5140 chassis front panel SlotFortiGate-5140 chassis back panel Slot numbersPhysical description of the FortiGate-5140 chassis FortiGate-5140 shelf managersLED FortiGate-5140 shelf alarm panel Shelf Manager fan and power controlShelf alarm panel telco alarms SerialShelf manager command line interface CLI Connecting to the shelf manager CLI using a serial portFortiGate-5140 Shelf Alarm Panel To add or change the shelf manager root account passwordTo use the shelf manager command line interface agent Clia Air filterCooling fan trays Cooling fan tray front panelCooling fan trays Power connection and configuration About data center DC powerConnecting a FortiGate-5140 PEM to data center DC power Terminal strip Connectors48V/-60 VDC nom RTN positive Connecting the FortiGate-5140 chassis to data center ground To connect a FortiGate-5140 PEM to data center DC powerConnector To connect the FortiGate-5140 chassis to data center groundFortiGate-5053 power converter tray front and back panel LED48V Basic power requirements Redundant FortiGate-5140 power suppliesRedundant FortiGate-5053 power converter trays Redundant FortiGate-5053 power converter trays+ 1 redundancy 48V/-60 VDC RTN positive Terminal strip Connectors Turning on FortiGate-5140 chassis power Wiring the FortiGate-5053 power converter trayTurning on FortiGate-5140 chassis power Mounting the FortiGate-5140 chassis Inserting 5000-series modules into a FortiGate-5140 chassisAir flow FortiGate-5140 hardware procedures Customer service and technical support Fortinet documentationRegister your Fortinet product Vcci