Page 1

FortiGate-5140-R

Chassis Guide

5140SAP

SERIAL 1

SERIAL 2

ALARM

5140

 

 

 

RESET

CAL

CRITI

MAJORMINOR USER1 USER2 USER3

13

11

 

9

 

7

 

5

 

3

1

2

4

 

6

 

8

 

10

 

12

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2

FILTER

0 FAN TRAY

1 FAN TRAY

2 FAN TRAY

Adetailed guide to the FortiGate-5140 chassis. This FortiGate-5140-R Chassis Guide describes FortiGate-5140 hardware features, and how to install the FortiGate-5140 chassis.

The most recent versions of this and all FortiGate-5000 series documents are available from the FortiGate-5000page of the Fortinet Technical Documentation web site (http://docs.forticare.com).

Visit http://support.fortinet.com to register your FortiGate-5140-R chassis. By registering you can receive product

updates, technical support, and FortiGuard services.

FortiGate-5140-R Chassis Guide

01-30000-87705-20090108

Image 1
Contents FortiGate-5140-R FortiGate-5140-R Chassis Guide Contents Comments on Fortinet technical documentation For more informationFortiGate-5140 chassis Slot FortiGate-5140 chassis front panelSlot numbers FortiGate-5140 chassis back panelFortiGate-5140 shelf managers Physical description of the FortiGate-5140 chassisLED Shelf Manager fan and power control FortiGate-5140 shelf alarm panelSerial Shelf alarm panel telco alarmsConnecting to the shelf manager CLI using a serial port Shelf manager command line interface CLITo add or change the shelf manager root account password FortiGate-5140 Shelf Alarm PanelAir filter To use the shelf manager command line interface agent CliaCooling fan tray front panel Cooling fan traysCooling fan trays About data center DC power Power connection and configurationTerminal strip Connectors Connecting a FortiGate-5140 PEM to data center DC power48V/-60 VDC nom RTN positive To connect a FortiGate-5140 PEM to data center DC power Connecting the FortiGate-5140 chassis to data center groundTo connect the FortiGate-5140 chassis to data center ground ConnectorLED FortiGate-5053 power converter tray front and back panel48V Redundant FortiGate-5140 power supplies Basic power requirementsRedundant FortiGate-5053 power converter trays Redundant FortiGate-5053 power converter trays+ 1 redundancy 48V/-60 VDC RTN positive Terminal strip Connectors Wiring the FortiGate-5053 power converter tray Turning on FortiGate-5140 chassis powerTurning on FortiGate-5140 chassis power Inserting 5000-series modules into a FortiGate-5140 chassis Mounting the FortiGate-5140 chassisAir flow FortiGate-5140 hardware procedures Fortinet documentation Customer service and technical supportRegister your Fortinet product Vcci