Turning on FortiGate-5140 chassis power

As well the Status LED on the FortiGate-5140 shelf manager front panels should be lit (see Figure 3 on page 9). None of the LEDs on the shelf alarm panel (SAP) should be lit (see Figure 4 on page 10). The shelf manager and shelf alarm panels are on the FortiGate-5140 front panel (see Figure 1 on page 6).

When the chassis first starts up you should also hear the chassis cooling fan trays operating.

In addition, if any FortiGate-5000 series modules have been installed in the chassis, they should power on and their front panel LEDs should indicate that they are operating normally.

FortiGate-5140-R Chassis Guide

2801-30000-87705-20090108http://docs.fortinet.com/ Feedback

Image 28
Contents FortiGate-5140-R FortiGate-5140-R Chassis Guide Contents For more information Comments on Fortinet technical documentationFortiGate-5140 chassis FortiGate-5140 chassis front panel SlotFortiGate-5140 chassis back panel Slot numbersPhysical description of the FortiGate-5140 chassis FortiGate-5140 shelf managersLED FortiGate-5140 shelf alarm panel Shelf Manager fan and power controlShelf alarm panel telco alarms SerialShelf manager command line interface CLI Connecting to the shelf manager CLI using a serial portFortiGate-5140 Shelf Alarm Panel To add or change the shelf manager root account passwordTo use the shelf manager command line interface agent Clia Air filterCooling fan trays Cooling fan tray front panelCooling fan trays Power connection and configuration About data center DC powerTerminal strip Connectors Connecting a FortiGate-5140 PEM to data center DC power48V/-60 VDC nom RTN positive Connecting the FortiGate-5140 chassis to data center ground To connect a FortiGate-5140 PEM to data center DC powerConnector To connect the FortiGate-5140 chassis to data center groundFortiGate-5053 power converter tray front and back panel LED48V Basic power requirements Redundant FortiGate-5140 power suppliesRedundant FortiGate-5053 power converter trays Redundant FortiGate-5053 power converter trays+ 1 redundancy 48V/-60 VDC RTN positive Terminal strip Connectors Turning on FortiGate-5140 chassis power Wiring the FortiGate-5053 power converter trayTurning on FortiGate-5140 chassis power Inserting 5000-series modules into a FortiGate-5140 chassis Mounting the FortiGate-5140 chassisAir flow FortiGate-5140 hardware procedures Fortinet documentation Customer service and technical supportRegister your Fortinet product Vcci