Fortinet 5140-R manual FortiGate-5140 chassis front panel, Slot

Page 6

FortiGate-5140 chassis front panel

FortiGate-5140 chassis

FortiGate-5140 chassis front panel

Figure 1 shows the front panel of a FortiGate-5140 chassis. Two FortiSwitch-5003A boards are installed in slots 1 and 2. Twelve FortiGate-5001A-DW boards installed in slots 3 to 14.

Figure 1: FortiGate-5140 chassis front panel with FortiGate-5001A-DW and FortiSwitch-5003A boards installed

FortiGate-5001A-DW

 

 

 

 

 

 

FortiGate-5001A-DW

 

boards

 

 

 

 

 

 

 

boards

slots 3, 5, 7, 9, FortiSwitch-5003A

slots 4, 6, 8, 10,

 

11, and 13

 

boards

12, and 14

 

 

 

slots 1

 

and 2

 

ESD socket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5140SAP

SERIAL 1

SERIAL 2

ALARM

5140

CRITICALMAJORMINOR USER1 USER2 USER3

 

 

 

RESET

 

 

 

Shelf alarm panel (SAP)

13

11

9

7

5

3

1

2

4

6

8

10

12

14

Slot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

numbers

ETH0 ETH1

5000SM

10/100 link/Act 10/100 link/Act

ETH0

Service

RESET

STATUS

Hot Swap

12

Primary

shelf manager

ETH0 ETH1

10/100 link/Act 10/100 link/Act

5000SM

 

 

Service

Secondary

 

 

ETH0

shelf manager

 

 

STATUS

 

 

RESET

 

 

 

Hot Swap

 

 

 

 

Front accessible

 

FILTER

 

air filter

 

 

 

Front cable

 

 

 

tray

 

 

 

Cooling fan

 

 

 

trays 0, 1, 2

0 FAN TRAY

1 FAN TRAY

2 FAN TRAY

 

The FortiGate-5140 shelf alarm panel (SAP) and primary and secondary FortiGate-5140 Shelf Managers are also visible. The factory installed shelf alarm panel displays alarms, provides a telco alarm interface, and also provides serial connections to the shelf managers. The factory installed shelf managers provide power distribution, cooling, alarms, and shelf status for the FortiGate-5140 chassis. For more information about these components, see “FortiGate-5140 shelf alarm panel” on page 10 and “FortiGate-5140 shelf managers” on page 8.

Caution: Do not operate the FortiGate-5140 chassis with open slots on the front panel. For optimum cooling performance and safety, the slots must contain a FortiGate-5000 series board or an air baffle slot filler. As well the removable terminal block cover must be installed over the power connectors on the back of the chassis.

FortiGate-5140-R Chassis Guide

601-30000-87705-20090108http://docs.fortinet.com/ Feedback

Image 6
Contents FortiGate-5140-R FortiGate-5140-R Chassis Guide Contents For more information Comments on Fortinet technical documentationFortiGate-5140 chassis FortiGate-5140 chassis front panel SlotFortiGate-5140 chassis back panel Slot numbersPhysical description of the FortiGate-5140 chassis FortiGate-5140 shelf managersLED FortiGate-5140 shelf alarm panel Shelf Manager fan and power controlShelf alarm panel telco alarms SerialShelf manager command line interface CLI Connecting to the shelf manager CLI using a serial portFortiGate-5140 Shelf Alarm Panel To add or change the shelf manager root account passwordTo use the shelf manager command line interface agent Clia Air filterCooling fan trays Cooling fan tray front panelCooling fan trays Power connection and configuration About data center DC powerConnecting a FortiGate-5140 PEM to data center DC power Terminal strip Connectors48V/-60 VDC nom RTN positive Connecting the FortiGate-5140 chassis to data center ground To connect a FortiGate-5140 PEM to data center DC powerConnector To connect the FortiGate-5140 chassis to data center groundFortiGate-5053 power converter tray front and back panel LED48V Basic power requirements Redundant FortiGate-5140 power suppliesRedundant FortiGate-5053 power converter trays Redundant FortiGate-5053 power converter trays+ 1 redundancy 48V/-60 VDC RTN positive Terminal strip Connectors Turning on FortiGate-5140 chassis power Wiring the FortiGate-5053 power converter trayTurning on FortiGate-5140 chassis power Mounting the FortiGate-5140 chassis Inserting 5000-series modules into a FortiGate-5140 chassisAir flow FortiGate-5140 hardware procedures Customer service and technical support Fortinet documentationRegister your Fortinet product Vcci