Falcon SG800-1T SG800VA-3kVA Tower Extended Battery Bank Selection Guide, For 800VA-1KVA Models

Page 10

SG800VA-3kVA TOWER EXTENDED BATTERY BANK SELECTION GUIDE

FOR 800VA-1KVA MODELS

BATTERY OPTION

 

 

 

 

 

MODELS

SGB2S7-1K3

SGB4S7-1K3

SGB5S7-1K3

SGB10S7-1K6

SGB10S7-1K6

W/O Charger

 

 

 

 

 

BATTERIES

6 Pieces 12V, 7AH

12 Pieces 12V, 7AH

15 Pieces 12V,

30 Pieces 12V, 7AH

60 Pieces 12V,

 

 

7AH

 

7AH

 

 

 

 

BATTERIES IN UPS

 

 

3 each of 12V, 7AH

 

 

# of CASES

1 Mini-Tower

1 Mini-Tower

1 Mini-Tower

1 Floor Standing

2 Floor Standing

Inches

13.8 x 7.6 x 18.9

13.8 x 7.6 x18.9

13.8 x 7.6 x18.9

32.1 x 10.2 x 21.8

32.1 x 10.2 x 21.8

(mm)

(350 x 193 x 480)

(350 x 193 x 480)

(350 x 193 x 480)

(814 x 259 x 554)

(814 x 259 x 554)

RUN TIME @ 100W

215 Min.

390 Min.

480 Min.

960 Min.

2000 Min.

RUN TIME @ 200W

107 Min.

210 Min.

255 Min.

520 Min.

1070 Min.

RUN TIME @ 400W

49Min.

96 Min.

120 Min.

255 Min.

550 Min.

RUN TIME @ 700W

23Min.

50 Min.

80 Min.

140 Min.

260 Min.

 

 

CHARGER OPTION

INFORMATION

 

 

BATTERY OPTION

 

 

 

 

 

MODELS

SGB2S7-1K3-1

SGB4S7-1K3-1

SGB5S7-1K3-1

SGB10S7-1K6-1

SGB10S7-1K6-1

With 120Vac Charger

 

 

 

 

 

BATTERY OPTION

 

 

 

 

 

MODELS

SGB2S7-1K3-2

SGB4S7-1K3-2

SGB5S7-1K3-2

SGB10S7-1K6-2

SGB10S7-1K6-2

With 200-240Vac

 

 

 

 

 

Charger

 

 

 

 

 

CHARGER OUTPUT

41.1Vdc @ 4.5A

41.1Vdc @ 4.5A

41.1Vdc @ 4.5A

41.1Vdc @ 4.5A

41.1Vdc @ 4.5A

# OF CHARGERS

1

1

1

2

4

 

 

 

 

 

 

 

FOR 1.5KVA-2KVA MODELS

BATTERY OPTION

SGB2S7-2K3

SGB2S7-2K3

SGB5S7-2K6

SGB2S7-2K3

SGB5S7-2K6

SGB5S7-2K6

MODELS

W/O Charger

 

 

 

 

 

 

BATTERIES

12 Pieces of 12V,

24 Pieces of 12V,

30 Pieces of 12V,

36 Pieces of 12V,

60 Pieces of 12V,

90 Pieces of 12V,

7AH

7AH

7AH

7AH

7AH

7AH

 

BATTERIES IN UPS

 

 

6 each of

12V, 7AH

 

 

# of CASES

1 Mini-Tower

2 Mini-Towers

1 Floor Standing

3 Mini-Towers

2 Floor Standing

3 Floor Standing

Inches

13.8 x 7.6 x 18.9

13.8 x 7.6 x 18.9

32.1 x 10.2 x 21.8

13.8 x 7.6 x 18.9

32.1 x 10.2 x 21.8

32.1 x 10.2 x 21.8

(mm)

(350 x 193 x 480)

(350 x 193 x 480)

(814 x 193 x 554)

(350 x 193 x 480)

(814 x 193 x 554)

(814 x 193 x 554)

RUN TIME @ 300W

170 Min.

310 Min.

390 Min.

470 Min.

760 Min.

1200 Min.

RUN TIME @ 500W

95 Min.

180 Min.

225 Min.

260 Min.

465 Min.

690 Min.

RUN TIME @ 700W

63 Min.

120 Min.

155 Min.

185 Min.

320 Min.

490 Min.

RUN TIME @ 1000W

39 Min.

79 Min.

100 Min.

120 Min.

215 Min.

330 Min.

RUN TIME @ 1400W

24 Min.

51 Min.

64 Min.

80 Min.

140 Min.

225 Min.

 

 

CHARGER

OPTION INFORMATION

 

 

BATTERY OPTION

 

 

 

 

 

 

MODELS

SGB2S7-2K3-1

SGB2S7-2K3-1

SGB5S7-2K6-1

SGB2S7-2K3-1

SGB5S7-2K6-1

SGB5S7-2K6-1

With 120Vac

 

 

 

 

 

 

Charger

 

 

 

 

 

 

BATTERY OPTION

 

 

 

 

 

 

MODELS

SGB2S7-2K3-2

SGB2S7-2K3-2

SGB5S7-2K6-2

SGB2S7-2K3-2

SGB5S7-2K6-2

SGB5S7-2K6-2

With 208-240Vac

 

 

 

 

 

 

Charger

 

 

 

 

 

 

CHARGER OUTPUT

82.5Vdc @ 4A

82.5Vdc @ 4A

82.5Vdc @ 4A

82.5Vdc @ 4A

82.5Vdc @ 4A

82.5Vdc @ 4A

#. OF CHARGERS

1

1

1

1

2

3

FOR 3KVA MODELS

BATTERY OPTION

 

 

 

 

 

 

MODELS

SGB2S7-3K3

SGB2S7-3K3

SGB5S7-3K6

SGB2S7-3K3

SGB5S7-3K6

SGB5S7-3K6

W/O Charger

 

 

 

 

 

 

BATTERIES

16 Pieces 12V,7AH

32 Pieces 12V, 7AH

40 Pieces 12V, 7AH

48 Pieces 12V, 7AH

80 Pieces 12V, 7AH

160 Pieces 12V, 7AH

BATTERIES IN UPS

 

 

8 each of

12V, 7AH

 

 

# of CASES

1 Mini-Tower

2 mini-Towers

1 Floor Standing

3 Mini-Towers

2 Floor Standing

4 Floor Standing

H x W x D

13.8 x 7.6 x 18.9

13.8 x 7.6 x 18.9

32.1 x 10.2 x 21.8

13.8 x 7.6 x 18.9

32.1 x 10.2 x 21.8

32.1 x 10.2 x 21.8

Inches

(350 x 193 x 480)

(350 x 193 x 480)

(814 x 259 x 554)

(350 x 193 x 480)

(814 x 259 x 554)

(814 x 259 x 554)

(mm)

 

 

 

 

 

 

RUN TIME @ 500W

135 Min.

260 Min.

310 Min.

380 Min.

640 Min.

1350 Min.

RUN TIME @ 1000W

59 Min.

115 Min.

140 Min.

170 Min.

300 Min.

620 Min.

RUN TIME @ 1500W

33 Min.

68 Min.

84 Min.

105 Min.

190 Min.

400 Min.

RUN TIME @ 2100W

20.5 Min.

43 Min.

57 Min.

69 Min.

125 Min.

270 Min.

 

 

CHARGER OPTION INFORMATION

 

 

BATTERY OPTION

 

 

 

 

 

 

MODELS

SGB2S7-3K3-1

SGB2S7-3K3-1

SGB5S7-3K6-1

SGB2S7-3K3-1

SGB5S7-3K6-1

SGB5S7-3K6-1

With 120Vac Charger

 

 

 

 

 

 

BATTERY OPTION

 

 

 

 

 

 

MODELS

SGB2S7-3K3-2

SGB2S7-3K3-2

SGB5S7-3K6-2

SGB2S7-3K3-2

SGB5S7-3K6-2

SGB5S7-3K6-2

With 208-240Vac

 

 

 

 

 

 

Charger

 

 

 

 

 

 

CHARGER OUTPUT

110Vdc @4.5A

110Vdc @4.5A

110Vdc @4.5A

110Vdc @4.5A

110Vdc @4.5A

110Vdc @4.5A

# OF CHARGERS

1

1

1

1

2

4

NOTE: The backup times stated are for reference only. Backup time may vary due to the type of load, battery age or condition, environmental conditions, etc.

8

Image 10
Contents Owners Operating Manual Table of Contents SG Series ON-LINE UPS System Block Diagram Important Safety Instructions True Regenerative On-Line Design Input Power Factor CorrectionExtended Battery Bank Option Microprocessor ControlInstallation Instructions Page SW1 Installation Procedure for Extended Battery Banks Typical Extended Battery Bank & UPS InterconnectionSG800VA-3kVA Tower Extended Battery Bank Selection Guide For 800VA-1KVA ModelsLoad Level Indicator Leds OperationInverter Indicator LED Category two alarms Audible AlarmsCategory one alarms = UPS Output Voltage is of RangeSG800-1T & SG1K-1T Typical Rear Panel Overview Rear Panel DetailsSG800-2T & SG1K-2T Typical Rear Panel Overview SG1.5K-1T, SG2K-1T & SG3K-1T Typical Rear Panel Overview SG1.5K-2T, SG2K-2T & SG3K-2T Typical Rear Panel OverviewBreaker Location Communications InterfacesSupported Protocols With on-bypass signal No on-bypass signalTypical Falcon Dry Contact Relay Board Typical Falcon Opto-coupler Interface Card No-bypass signalOpto Board Internal Circuitry APC Style Dry Contact Relay Board APC Style BoardBattery Life vs. Temperature Care & MaintenanceBattery Replacement Storing the UPS and Batteries FCC ConsiderationsSUPPORT@FALCONUPS.COM Technical SupportRequesting Technical Information or Support 800.842.6940 Falcon Web SupportNEW Product Limited Warranty Falcon ELECTRIC, INCSG SeriesTM UPS Plus 2kVA 3kVA 2kVA & 3kVA