Enterasys Networks 2000 manual LFH-60 high density connector pin assignments Pin Signal

Page 54

Installing the Hardware

Dual Serial and Quad Serial – C/CE Expansion Modules

The Dual Serial and Quad Serial – C/CE expansion modules each use the same 60-pin LFH-60 high density connector to link to their respective Channel Service Units/Data Service Units (CSU/DSUs). Figure 23 on page 39 shows how to plug your serial cable into a port on the Dual Serial or Quad Serial – C/CE expansion modules.

Enterasys offers the following four cables, used to connect the XP to standard CSU/DSU modules:

Table 19. Enterasys dual serial port to CSU/DSU connector cables

Enterasys Part Number

CSU/DSU Connector Type

Standard

 

 

 

SYS-SV35-DTE

Two (2) V.35 34-pin connectorsa

V.35

SYS-S530-DTE

Two (2) DB-25 25-pin connectors

EIA-530

 

 

 

SYS-S449-DTE

Two (2) DB-37 37-pin connectors

RS-449

 

 

 

SYS-SX21-DTE

Two (2) DB-15 15-pin connectors

X.21

 

 

 

a.The two remote ends of each type of connector cable is labeled “Port A” and “Port B”. “Port A” corresponds to Port 1 on a Dual Serial WAN expansion module and Port 1 or 3 on a

Quad Serial – C/CE, depending upon which WAN expansion module port you are using. Similarly, “Port B” corresponds to Port 2 on a Dual Serial WAN expansion module and Port 2 or 4 on a Quad Serial – C/CE.

Note: Because the LFH-60 high density connectors on Dual Serial and Quad

Serial – C/CE expansion modules contain two serial WAN ports per interface, all four cable types defined above feed two CSU/DSU ports.

Table 20 maps the pin assignments for Enterasys’ LFH-60 high density connectors for the Dual Serial and Quad Serial – C/CE expansion modules.

Table 20. LFH-60 high density connector pin assignments

Pin

Signal

Pin

Signal

Pin

Signal

Pin

Signal

 

 

 

 

 

 

 

 

1

P1_GND

16

P2_TXC_A

31

P1_GND

46

P2_TXD_A

 

 

 

 

 

 

 

 

2

P1_MODE[2]

17

P2_TXC_B

32

P1_MODE[0]

47

P2_TXD_B

 

 

 

 

 

 

 

 

3

P1_CTS_B

18

P2_DCD_A

33

P1_DCD_B

48

P2_RTS_A

 

 

 

 

 

 

 

 

4

P1_CTS_A

19

P2_DCD_B

34

P1_DCD_A

49

P2_RTS_B

 

 

 

 

 

 

 

 

5

P1_RTS_B

20

P2_MODE[1]

35

P0_RXD_B

50

P2_DSR_A

 

 

 

 

 

 

 

 

6

P1_RTS_A

21

P2_GND

36

P0_RXD_A

51

P2_DSR_B

 

 

 

 

 

 

 

 

7

P1_SCTE_B

22

P2_GND

37

Reserved

52

P2_LL_A

 

 

 

 

 

 

 

 

8

P1_SCTE_A

23

P1_TXD_A

38

P2_GND

53

P2_SHIELD

 

 

 

 

 

 

 

 

38

Enterasys Xpedition 2000 Getting Started Guide

Image 54
Contents 2000 Page FCC Notice Enterasys X-Pedition 2000 Getting Started Guide Enterasys NETWORKS, INC Program License Agreement Enterasys X-Pedition 2000 Getting Started Guide Enterasys X-Pedition 2000 Getting Started Guide Vii Declaration of Conformity Contents Hardware Installation Appendix a Troubleshooting IndexContents Xii Enterasys X-Pedition 2000 Getting Started Guide Who should Read this Guide? How to Use this GuideWhat’s New If You Want To SeeRelated Documentation Getting HelpFor Information About See Preface Preface Xvi Enterasys X-Pedition 2000 Getting Started Guide Chapter Features Overview SpecificationsIPX RIP, SAP RmonSnmp TCP/UDP services TCP Port UDP Port Description FeaturesTCP/UDP Services LLCBridging Port and Protocol VLANsRouting IP Routing IP Multicast RoutingIPX Routing Layer-4 Switching SecurityManagement Platforms Quality of ServiceStatistics VlanHardware Overview ChassisExternal Controls Motherboard FeaturesBoot Flash Status LEDs LED Label DescriptionPower Supplies FansRAM Memory Expansion Modules 10/100BASE-TX Expansion ModuleCabling and Connector Specifications LEDs100BASE-TX expansion module LEDs 100BASE-FX Expansion Module Front panel of 100BASE-FX expansion moduleBASE-FX expansion module LEDs 1000BASE-SX Expansion ModuleBASE-SX expansion module LEDs 1000BASE-LX Expansion Module Front panel of 1000BASE-LX expansion moduleBASE-LX expansion module LEDs Dual Serial and Quad Serial C/CE Expansion Modules Front panel of Dual Serial WAN expansion moduleDual Serial and Quad Serial C/CE WAN expansion module LEDs Port Type Specification Dual Hssi Line CardHssi LED Page Safety Considerations Preventing InjuryXP-2000 physical and environmental specifications Hardware SpecificationsInstalling the Hardware Preventing Equipment DamageVerifying Your Shipment Installing the Chassis Table-Top InstallationRack Mount Installation Installing the XP-2000 chassis in an equipment rack Connecting Power to the Chassis Installing an Expansion ModuleInstalling the new face plate view from inside chassis Front of XP-2000 Attaching the Console Management Cables Nteras ys Net worksConnecting to the Serial Port Plugging into the XP-2000’s serial DB-9 DCE portConnecting to the 10/100Base-TX Port Plugging into the XP-2000’s 10/100Base-TX portAttaching Port Cables RXD receive data TXD transmit dataPlugging an ethernet cable into a 10/100BASE-TX port 100BASE-TX RJ-45 connector 1000BASE-SX and 1000BASE-LX Expansion Modules LFH-60 high density connector pin assignments Pin Signal P1GND P1TXDB P2GND P1TXCA P2CTSB P1RXCAP2SCTEB P1LLA P2RXCA P1GND P2SCTEA P1SHIELD Pin Signal Pin Hssi connector Page Chapter Firmware Installation Setup Powering On and Booting the FirmwareStarting the Command Line Interface Access ModesBasic Line Editing Commands Some commonly used CLI commands Key sequence CommandSetting Basic System Information Here is an exampleEnter yes or y to activate the changes Setting Up Snmp Community Strings Enter the copy active to startup commandSetting Up Snmp Community Strings READ-WRITE Setting Up Passwords Xp-1#system show active-configSetting the DNS Domain Name and Address Xp-1#pingSetting Syslog Parameters System set dns server IP-address IP-address IP-addressSetting Syslog Parameters Ping IP-addr Loading System Image Firmware System image add IPaddr-of-TFTP-host image-file-name Enter the system image list command to verify the change Loading Boot Prom Firmware Xp-1#system promimage upgrade 10.50.11.12 prom2Upgrading the VFS Activating the Configuration Commands in the Scratchpad Viewing the Current ConfigurationCommand like stp enable et.*.* would be displayed as follows Appendix a Troubleshooting If you experience this difficulty Try this remedyUse the procedure in Activating the Configuration Appendix B Technical Support Getting Help Numerics DvmrpIgmp IPX SAPNvram Layer-4 flow 6 services User mode VLANs UDPIndex Enterasys X-Pedition 2000 Getting Started Guide
Related manuals
Manual 188 pages 39.25 Kb

2000 specifications

Enterasys Networks, a key player in the networking space in 2000, was renowned for its innovative solutions that combined high-performance networking with robust security features. Founded with the vision of providing enterprise-level networking infrastructure, Enterasys positioned itself to cater to the growing demands of business networks during the dot-com boom.

One of the main features of Enterasys Networks was its focus on delivering secure, scalable networking solutions that could seamlessly integrate with existing enterprise systems. The company developed a range of products including switches, routers, and wireless solutions that were designed to optimize performance while ensuring security at every layer. Their core offerings provided businesses with the reliability required to handle increasing volumes of data traffic.

A standout technology of Enterasys was its identity and access management solutions. These technologies allowed organizations to control who could access network resources and under what conditions. This was particularly crucial in a time when cyber threats were on the rise, and businesses were becoming more aware of the need for strict network security protocols. The features included role-based access control and authentication measures, which were fundamental in safeguarding sensitive information.

Enterasys also introduced intelligent networking features, which enabled dynamic traffic management and prioritization. This technology helped organizations optimize their network performance by automatically adjusting to changing workload demands. Such capabilities were essential for businesses relying on bandwidth-intensive applications and services.

The company also embraced the rising trend of wireless networking, providing solutions that combined wired and wireless technologies for a unified experience. Enterasys Wireless LAN solutions were groundbreaking at the time, offering seamless connectivity and security to mobile devices, thereby enhancing productivity and flexibility within enterprise environments.

In addition to hardware, Enterasys developed network management software that simplified the administration of complex networks. This software enabled IT professionals to monitor performance, troubleshoot issues, and implement security policies efficiently.

Overall, Enterasys Networks in 2000 was characterized by its commitment to delivering secure, intelligent networking solutions that catered to the needs of modern enterprises. With its innovative technologies and features, Enterasys played a significant role in shaping the networking landscape, laying the groundwork for future advancements in network security and management.