| Using LANVIEW |
|
Table |
|
|
| ||
|
|
|
|
| |
LED | Color | State | Recommended Action |
| |
|
|
|
|
|
|
UP | Off | No valid connection to switch stackdown | 1. | Make sure the switch connected to the |
|
|
| connector. |
| stackdown connector is powered on. |
|
|
|
| 2. | Replace cable with a known good one. |
|
|
|
| 3. | If the problem still exists, contact |
|
|
|
|
| Enterasys Networks for technical |
|
|
|
|
| support. |
|
|
|
|
|
| |
| Green | Solid. Valid connection to switch stackdown | None. |
| |
|
| connector. |
|
|
|
|
| Blinking. Information is being transferred via the |
|
|
|
|
|
|
|
| |
|
|
|
|
| |
Manager | Off | Switch is operating as a Member in the stack. | None. |
| |
|
|
|
|
| |
| Green | Solid. Switch is operating as the Manager of the | None. |
| |
|
| stack. |
|
|
|
|
|
|
|
| |
RPS | Off | RPS not in use. | None. |
| |
|
| Internal power supply failure. | If an RPS is connected to the switch, it |
| |
|
|
| should be providing power, perform the |
| |
|
|
| following: |
| |
|
|
| 1. | Ensure the RPS is powered on. |
|
|
|
| 2. | Ensure that the AC power cord to the |
|
|
|
|
| RPS is plugged in correctly and that |
|
|
|
|
| there is power at the AC power source. |
|
|
|
| 3. | Replace the power cord with a known |
|
|
|
|
| good one. |
|
|
|
| 4. | Ensure the DC power cord from the |
|
|
|
|
| RPS to the switch is plugged in |
|
|
|
|
| correctly. |
|
|
|
| 5. | If the problem persists, contact |
|
|
|
|
| Enterasys Networks for technical |
|
|
|
|
| support. |
|
|
|
|
|
| |
| Amber | Solid. The switch internal power supply failed, | None. |
| |
|
| and the RPS is providing the proper power to the |
|
|
|
|
| switch. |
|
|
|
Enterasys SecureStack B2 Installation Guide