Enterasys Networks IRM2 manual Resetting a Circuit, Redundancy Reset Warning Window

Page 83

Redundancy

NOTE

Any backup port which has been part of an enabled circuit will remain disabled by management until you turn it back on at the Chassis View window (in Logical mode), so that accidental data loops do not occur. Be sure to disconnect any redundant network links before re-enabling ports.

To change a port’s designation from primary to backup, or vice versa:

1.On the altered Chassis View, click on the port whose designation you wish to change.

2.Select Primary or Backup, as appropriate, to change the port’s designation.

Note that changing a port’s designation as primary or backup will not change its current active or inactive status; if you wish to activate a port you have just changed from backup to primary, or deactivate a port you have just changed from primary to backup, you must also use the Activate and Deactivate commands described above.

Resetting a Circuit

Resetting a circuit changes the status of the circuit to disabled, deletes all entries in the Polling Address list, and clears all port designations. You can reset circuits individually or collectively.

To reset an individual circuit:

1.Use the drop-down list to display the appropriate circuit in the Current Circuit text box; note that the current status of the selected circuit (enabled or disabled) is displayed just below the Current Circuit text box.

2.Click on Configure, and select Reset. This will clear all redundancy settings for the selected circuit, and restore it to its original undefined and disabled status.

To reset all circuits at once:

1.Click Reset. A warning window will appear (Figure 7-8), asking you to confirm your selection.

Figure 7-8. Redundancy Reset Warning Window

Reconfiguring a Circuit

7-11

Image 83
Contents IRM2 Users Guide Page Virus Disclaimer Page Restricted Rights Notice Page Contents Statistics Chapter Trap SelectionIndex Chapter RedundancyContents Viii Introduction Using This ManualIntroduction Related ManualsSoftware Conventions Using the MouseDevice Name Common IRM2 Window FieldsUsing Window Buttons Getting Help Using On-line HelpHours a day, 365 days a year Getting Help from the Enterasys Global Call CenterIntroduction Getting Help IRM2 Chassis View Viewing Chassis Information Port Status Front Panel InformationPort Locking/Unlocking Connection StatusTime Boot PromMenu Structure FirmwareDevice Menu IRM2 Chassis View Menu StructureRepeater Menu View MenuPort Status Menu Board Menu Utilities MenuHelp Menu Load MIM Port Status DisplaysPort Menus Status Port TypeErrors Port Status Color Codes Physical Chassis ViewChassis Manager Window Device Type Viewing Hardware TypesManaging the Hub Setting the Device Date and TimeRestarting the Device Resetting Device CountersRepeater Port Association Configuring the Front Panel Repeater Port AssociationEnabling Boards Setting a Board NameViewing I/F Summary Information Enabling and Disabling PortsPhysical Status IndexType DescriptionRaw Counts Viewing Interface Detail RateNon-Unicast ErrorAddress UnicastPackets Transmitted Transmit only Unknown Protocol Received onlyPackets Received Received only Transmit Queue Size Transmit onlyUsing the Applications menu Testing and Disabling the Current InterfaceStatistics StatisticsStatistics Accessing the Statistics WindowsPackets Statistics DefinedBytes Collisions Using the Total and Delta Radio ButtonsHard Errors Soft ErrorsAccessing the Timer Statistics Windows Timer StatisticsTo access the port-level Timer Statistics window Summary Statistics Setting the Timer Statistics IntervalAccessing the Summary Statistics Windows Configuring Summary Statistics Performance Graph Accessing the Performance Graph WindowsTotal Errors Configuring the Performance Graph Find Source Address Source Address FunctionsSource Address Functions Using Port Locking and UnlockingLock/Unlock Ports Window Using Source Addressing Setting the Device Ageing Time Device Ageing Time Window Accessing the Alarm Limits Windows Alarm LimitsAccessing the Alarm Limits Windows Alarm Limits Collisions Broadcast Packets Errors of TypeWithin Configuring AlarmsSetting the Alarm Limits Time Interval Alarm Interval Window Setting Alarm LimitsAlarm Limits Trap Selection Accessing the Trap Selection WindowsLink State Traps Trap DefinitionsSource Address Traps Segmentation TrapsConfiguring Traps Redundancy Accessing the Redundancy WindowRedundancy Selecting and Naming a Circuit Establishing RedundancyCircuit Name Window Entering the Physical Addresses of Devices to be PolledAssigning Backup Ports and Port Priority to the Circuit Polling Interval Window Setting the Polling Interval and Number of RetriesActivating the Circuit Testing the Circuits Test Time of Day Window Reconfiguring a CircuitChanging Port Status Redundancy Reset Warning Window Resetting a CircuitRedundancy Index Index-2 Index-3 Index Index-4