STK17T88
Software-Controlled STORE/RECALL Cycle
In the following table, the software controlled STORE and RECALL cycle parameters are listed. [12, 13]
NO. |
|
| Symbols | Parameter | Units | Notes | |||||||
| E Cont | Alternate | Min |
| Max | Min | Max | ||||||
|
|
|
|
|
| ||||||||
26 | tAVAV | tRC | STORE / RECALL Initiation Cycle Time | 25 |
|
| 45 |
| ns | 13 | |||
27 | tAVEL | tAS | Address | 0 |
|
|
| 0 |
| ns |
| ||
28 | tELEH | tCW | Clock Pulse Width | 20 |
|
| 30 |
| ns |
| |||
29 | tEHAX |
| Address Hold Time | 1 |
|
|
| 1 |
| ns |
| ||
30 | tRECALL |
| RECALL Duration |
|
|
| 100 |
| 100 | ms |
| ||
|
|
|
|
| Figure 10. Software Store/Recall Cycle: |
| CONTROLLED[13] |
|
|
| |||
|
|
|
|
| E |
|
|
| |||||
|
|
|
|
| 26 | 26 |
|
|
|
|
|
|
|
|
|
|
| 27 | 28 |
|
|
|
|
|
|
|
|
|
|
|
|
| 29 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 23 | 30 |
|
|
|
Notes
12.The software sequence is clocked on the falling edge of E controlled READs
13.The six consecutive addresses must be read in the order listed in the Software STORE/RECALL Mode Selection Table. W must be high during all six consecutive cycles.
Document Number: | Page 9 of 22 |
[+] Feedback