STK17T88
RTC Register Map
Register |
|
| BCD Format Data |
|
|
| Function / Range | |||
D7 | D6 | D5 | D4 | D3 | D2 | D1 | D0 | |||
|
| |||||||||
0x7FFF |
| 10s Years |
|
| Years |
| Years: | |||
0x7FFE | 0 | 0 | 0 | 10s |
| Months |
| Months: | ||
|
|
|
| Months |
|
|
|
|
| |
0x7FFD | 0 | 0 | 10s Day of Month |
| Day of Month |
| Day of Month: | |||
0x7FFC | 0 | 0 | 0 | 0 | 0 | Day of Week |
| Day of week: | ||
0x7FFB | 0 | 0 | 10s Hours |
| Hours |
| Hours: | |||
0x7FFA | 0 |
| 10s Minutes |
| Minutes |
| Minutes: | |||
0x7FF9 | 0 | 10s Seconds |
| Seconds |
| Seconds: | ||||
0x7FF8 | OSCEN | 0 | Cal |
| Calibration [00000] |
| Calibration values* | |||
| [0] |
| Sign |
|
|
|
|
|
| |
0x7FF7 | WDS | WDW |
|
| WDT |
|
| Watchdog* | ||
0x7FF6 | WIE[0] | AIE[0] | PFE[0] | 0 | H/L [1] | P/L [0] | 0 | 0 | Interrupts* | |
0x7FF5 | M | 0 | 10s Alarm Date |
| Alarm Day |
| Alarm, Day of Month: | |||
0x7FF4 | M | 0 | 10s Alarm Hours |
| Alarm Hours |
| Alarm, hours: | |||
0x7FF3 | M | 10 Alarm Minutes |
| Alarm Minutes |
| Alarm, minutes: | ||||
0x7FF2 | M | 10 Alarm Seconds |
| Alarm Seconds |
| Alarm, seconds: | ||||
0x7FF1 |
| 10s Centuries |
|
| Centuries |
| Centuries: | |||
0x7FF0 | WDF | AF | PF | OSCF | 0 | CAL[0] | W[0] | R[0] | Flags* |
*A binary value, not a BCD value.
0 - Not implemented, reserved for future use.
Default Settings of nonvolatile Calibration and Interrupt registers from factory Calibration Register=00h
Interrupt Register=00h
The User should configure to the desired value at startup or during operation and the value is then retained during a power failure. [ ] designates values shipped from the factory. See Stopping and Starting the RTC Oscillator on page 14.