Calibrating the Clock

The RTC is driven by a quartz controlled oscillator with a nominal frequency of 32.768 kHz. Clock accuracy depends on the quality of the crystal and calibration. The crystal oscillators typically have an error of +20ppm to +35ppm. However, CY14B256K employs a calibration circuit that improves the accuracy to +1/–2 ppm at 25°C. This implies an error of +2.5 seconds to -5 seconds per month.

The calibration circuit adds or subtracts counts from the oscillator divider circuit to achieve this accuracy. The number of pulses that are suppressed (subtracted, negative calibration) or split (added, positive calibration) depends upon the value loaded into the five calibration bits found in Calibration register at 0x7FF8. The calibration bits occupy the five lower order bits in the Calibration register. These bits are set to represent any value between ‘0’ and 31 in binary form. Bit D5 is a sign bit, where a ‘1’ indicates positive calibration and a ‘0’ indicates negative calibration. Adding counts speeds the clock up and subtracting counts slows the clock down. If a binary ‘1’ is loaded into the register, it corre- sponds to an adjustment of 4.068 or –2.034 ppm offset in oscil- lator error, depending on the sign.

Calibration occurs within a 64 minute cycle. The first 62 minutes in the cycle may, once per minute, have one second shortened by 128 or lengthened by 256 oscillator cycles. If a binary ‘1’ is loaded into the register, only the first two minutes of the 64 minute cycle is modified. If a binary 6 is loaded, the first 12 are affected, and so on. Therefore, each calibration step has the effect of adding 512 or subtracting 256 oscillator cycles for every 125,829,120 actual oscillator cycles, that is, 4.068 or –2.034 ppm of adjustment per calibration step in the Calibration register.

To determine the required calibration, the CAL bit in the Flags register (0x7FF0) must be set to ‘1’. This causes the INT pin to toggle at a nominal frequency of 512 Hz. Any deviation measured from the 512 Hz indicates the degree and direction of the required correction. For example, a reading of 512.01024 Hz indicates a +20 ppm error. Hence, a decimal value of –10 (001010b) must be loaded into the Calibration register to offset this error.

Note Setting or changing the Calibration register does not affect the test output frequency.

To set or clear CAL, set the write bit “W” (in the flags register at 0x7FF0) to “1” to enable writes to the Flag register. Write a value to CAL, and then reset the write bit to “0” to disable writes.

Alarm

The alarm function compares user programmed values of alarm time and date (stored in the registers 0x7FF1-5) with the corre- sponding time of day and date values. When a match occurs, the alarm internal flag (AF) is set and an interrupt is generated on INT pin if Alarm Interrupt Enable (AIE) bit is set.

There are four alarm match fields - date, hours, minutes, and seconds. Each of these fields has a match bit that is used to determine if the field is used in the alarm match logic. Setting the match bit to ‘0’ indicates that the corresponding field is used in

the match process. Depending on the match bits, the alarm occurs as specifically as once a month or as frequently as once every minute. Selecting none of the match bits (all 1s) indicates that no match is required and therefore, alarm is disabled. Selecting all match bits (all 0s) causes an exact time and date match.

There are two ways to detect an alarm event: by reading the AF flag or monitoring the INT pin. The AF flag in the flags register at 0x7FF0 indicates that a date or time match has occurred. The AF bit is set to “1” when a match occurs. Reading the flags or control register clears the alarm flag bit (and all others). A hardware interrupt pin may also be used to detect an alarm event.

Note CY14B256K requires the alarm match bit for seconds (0x7FF2 - D7) to be set to ‘0’ for proper operation of Alarm Flag and Interrupt.

Alarm registers are not nonvolatile and, therefore, need to be reinitialized by software on power up. To set, clear or enable an alarm, set the ‘W’ bit (in Flags Register - 0x7FF0) to ‘1’ to enable writes to Alarm Registers. After writing the alarm value, clear the ‘W’ bit back to “0” for the changes to take effect.

Watchdog Timer

The Watchdog Timer is a free running down counter that uses the 32 Hz clock (31.25 ms) derived from the crystal oscillator. The oscillator must be running for the watchdog to function. It begins counting down from the value loaded in the Watchdog Timer register.

The timer consists of a loadable register and a free running counter. On power up, the watchdog time out value in register 0x7FF7 is loaded into the Counter Load register. Counting begins on power up and restarts from the loadable value any time the Watchdog Strobe (WDS) bit is set to ‘1’. The counter is compared to the terminal value of ‘0’. If the counter reaches this value, it causes an internal flag and an optional interrupt output. You can prevent the time out interrupt by setting WDS bit to ‘1’ prior to the counter reaching ‘0’. This causes the counter to reload with the watchdog time out value and to be restarted. As long as the user sets the WDS bit prior to the counter reaching the terminal value, the interrupt and WDF flag never occur.

New time out values are written by setting the watchdog write bit to ‘0’. When the WDW is ‘0’, new writes to the watchdog time out value bits D5-D0 are enabled to modify the time out value. When WDW is ‘1’, writes to bits D5-D0 are ignored. The WDW function enables a user to set the WDS bit without concern that the watchdog timer value is modified. A logical diagram of the watchdog timer is shown in Figure 4. Note that setting the watchdog time out value to ‘0’ disables the watchdog function.

The output of the watchdog timer is the flag bit WDF that is set if the watchdog is allowed to time out. The flag is set upon a watchdog time out and cleared when the user reads the Flags or Control registers. If the watchdog time out occurs, the user also enables an optional interrupt source to drive the INT pin.

Document Number: 001-06431 Rev. *H

Page 8 of 28

[+] Feedback

Image 8
Contents Features Logic Block DiagramFunctional Description Cypress Semiconductor Corporation 198 Champion CourtPin Configurations Pin DefinitionsHardware Store HSB Operation Device OperationAutoStore Operation Hardware Recall Power Up Software StoreSoftware Recall Data ProtectionLow Average Active Power Best Practices Current versus Cycle TimeMode Selection A13-A0 Power Real Time Clock Operation Calibrating the Clock AlarmWatchdog Timer Power Monitor InterruptsInterrupt Register Flags RegisterInterrupt Block Diagram RTC Register Map5 BCD Format Data Function/Range WDF OscfRegister Map Detail Time Keeping Years 0x7FFF 10s Years Time Keeping Months 0x7FFE 10s MonthDate Time Keeping Hours 0x7FFB Time Keeping Minutes 0x7FFAAlarm Day 0x7FF5 Register Map Detail Calibration/Control 0X7FF80x7FF7 Interrupt Status/Control 0x7FF6Register Map Detail Alarm Hours 0x7FF4 10s Alarm Hours To ignore the hours value Alarm Minutes 0x7FF3Alarm Seconds 0x7FF2 When the Flags register is read or on power-upDC Electrical Characteristics Maximum RatingsOperating Range RangeData Retention and Endurance CapacitanceThermal Resistance AC Test ConditionsAC Switching Characteristics Parameter Sram Read CycleParameter Cypress Alt Description 25 ns 35 ns 45 ns Min Max Unit Sram Write CycleAutoStore or Power Up Recall Parameter Description CY14B256K Unit Min MaxSoftware Controlled STORE/RECALL Cycles 20 Parameter Alt Description 25 ns 35 ns 45 ns Unit Min MaxSoft Sequence Commands Hardware Store CycleTruth Table For Sram Operations RTC CharacteristicsInputs and Outputs Mode Power Part Numbering Nomenclature CY 14 B 256 K SP 25 X C T Ordering Information Package Diagrams Pin Shrunk Small Outline PackageDocument History Orig. of Change Submission Description of Change DateUpdated Features section Updated Reading the clock, Backup Power, StoppingStarting the Oscillator and Alarm descriptions under RTC Added default values to RTC Register Map tableUSB Sales, Solutions, and Legal InformationWorldwide Sales and Design Support Products PSoC Solutions