Furuno ETR-30N manual Transducer type setting options, Frequency input screen

Page 29

Transducer connected to the ETR-30N is not programmed in the ETR-30N

For the transducer not programmed in the ETR-30N, enter its frequency manually as below.

CAUTION

Do not enter transducer specifications manually if the transducer is programmed in the equipment.

The transducer may become damaged.

1.Follow the procedure on page 7 to shown the INSTALLATION SETUP menu.

2.Press the NETWORK SOUNDER SETUP soft key.

3.Press the FREQ SETUP soft key.

4.Press the EDIT soft key.

TRANSDUCER SETUP

MODEL NUMBER

MANUAL

Transducer type setting options

5.Use the [ENTER] knob to select MANUAL and then push the [ENTER] knob.

6.Use the [ENTER] knob to choose HIGH FREQUENCY and then push the [ENTER] knob.

HIGH FREQUENCY

12.0kHz

Frequency input screen

7.Use the [ENTER] knob to choose frequency (setting range: 25 kHz-220 kHz) and then push the [ENTER] knob. Currently, 12-24.8 kHz and 221-420 kHz cannot be set. These frequencies are for future use.

8.If a low-frequency transducer is installed, set it similarly.

9.Turn off the NavNet display unit.

10.Turn on the Navnet display unit. Confirm that the echo sounder picture advances.

11

Image 29 Contents
Network Sounder Safety Instructions Be sure to enter transducer model correctly Table of Contents Single network sounder System ConfigurationSystem configuration, single network sounder Multiple network sounders System configuration, two ETR-30NSystem configuration, ETR-30N + ETR-6/10N Standard supply Equipment ListsOptional supply Name Type Code No Qty Remarks1kW transducer Available transducersVii 1kW transducer con’t Viii2kW transducer 3kW transducer 3kW transducer con’t 1kW/2kW transducer Xii1kW/3kW transducer Xiii1kW/2kW transducer con’t 1kW/3kW transducer con’t Xiv200B-12H 3 k 88/150 Steel 88B-8 2kW/3kW transducer Xvi3kW/2kW transducer con’t XviiMounting dimensions for the network sounder Mounting procedureMounting Network SounderHow to assemble the piggyback mount kit Contents of piggyback mount kitTransducer Stacking unitsWiring WIRING, SetupStandard installation Connection of network sounderGround How to attach connector to transducer cableTransducer Network HUB Connection of multiple network soundersNetwork sounder ETR-30N, top view, cover removed Settings for Single Network SounderInternal settings Furuno Sounder source settingNetwork setup menu Simulation mode windowHost Name Transducer setupSounder setup Frequency options Frequency setup screenTransducer type setting method options Frequency input screen Transducer type setting optionsSettings for Two Network Sounders NET KP ETR-30N and ETR-6/10N ETR-30N, cover removed Erasing Transducer SettingNetwork sounder ETR-30N OPERATION, MaintenanceControls Choosing pulse repetition rate PRR Sounder system setup menuAdditions to NavNet Series Operator’s Manual Transducer frequency Replacing FusesCPU Board All ClearThis page is intentionally left blank Transducer, thru-hull pipe and tank list Appendix NEW BLT TransducersAP-1 AP-2 SettingsETR-30N List Packing List Page Page Page Page 00080932900