Furuno MU-150C MAINTENANCE, Troubleshooting, Maintenance, Routine maintenance, Fuse replacement

Page 21

5MAINTENANCE, TROUBLESHOOTING

WARNING

ELECTRICAL SHOCK HAZARD

Do not open the equipment.

Only qualified personnel should work inside the equipment.

5.1 Maintenance

Routine maintenance

Regular maintenance is important for good performance. Check the following on a regular basis to keep the equipment in good operating condition.

Check that the connectors at the rear of the display unit are tightly fastened.

Check the ground wire and ground terminal for rust. Clean if necessary. Confirm that the ground wire is tightly fastened.

Remove dust and dirt from the display unit and LCD with a dry, soft cloth. Do not use chemical cleaners to clean any part of the display unit – they can remove paint and markings.

Wipe the LCD carefully o prevent scratching, using tissue paper and an LCD cleaner. To remove dirt or salt deposits, use an LCD cleaner, wiping slowly with tissue paper so as to dissolve the dirt or salt. Change paper frequently so the salt or dirt will not scratch the LCD. Do not use solvents such as thinner, acetone or benzene for cleaning.

Fuse replacement

The 1.5 A 250 V fuse (AC type) or 3A 125V fuse (DC type) on the rear panel protects the equipment from internal fault and overcurrent. If the fuse blows, find the cause before replacing it. If the fuse blows again after replacement, request service.

WARNING

Use the proper fuse.

Use of a wrong fuse can cause fire or damage to the equipment.

14

Image 21
Contents MULTI-PURPOSE LCD Display Page Safety Instructions Table of Contents Foreword FeaturesWord to the Owner of the MU-150C IiiConnectable equipment System ConfigurationEquipment Lists Standard supplyOption Mounting Display UnitFlush mounting Display unit and cover Mounting dimensionsDesktop mounting Mounting base lowerFastening bracket and mounting plate to mounting base upper Connection of cables at the rear of the display unit Fastening the front panelFastening the mounting base lower to the display unit Hood option Display unit, how to attach Velcro tapesWiring Wiring External EquipmentGeneral-purpose monitor Display unit, rear view, wiring using specialty cables Connecting FCV-1200 series and CH-250Sub connector Rear panel AC type AdjustmentsAbout the picture adjustment buttons Picture AdjustmentRGB Adjustment Brilliance AdjustmentJumper blocks Display unit OperationMaintenance MAINTENANCE, TroubleshootingRoutine maintenance Fuse replacementTroubleshooting table TroubleshootingAppendix AP-1Display unit, rear view AP-2 Power assyAP-3 AP-4 Location of power switch and pcb 10P3879MU-150C Specifications of MULTI-PURPOSE LCD DisplayThis page is intentionally left blank Packing List MU-150C-H-AC-CS Page Page Page Page Page Page Page Page Page 00080923101