Connecting FCV-1200 series and CH-250
Using the cables designated below (or equivalent) to connect the FCV-1200 series or CH-250 makes their interface unit of the FCV-1200 series and CH-250 unnecessary. The mini D-SUB 15 P connector cannot be used to connect the FCV-1200 series and CH-250.
Navigator, etc.
| 06S4078 |
24 VDC | FCV-1200 Series: |
or 100-240 VAC | PROCESSOR UNIT CN1 |
Ground | CH-250: TRANSCEIVER UNIT |
Terminal | DATA/VIDEO OUT |
FCV-1200 Series: CONTROL UNIT
MJ-A10SPF0002-015CONT
CH-250: CONTROL UNIT
REM CONT
Display unit, rear view, wiring using specialty cables
Notes on wiring
•For AC specification, solder connector SRCN6A13-3S (supplied in installation materials) to the power cable (DPYC-1.5 (Japan Industrial Standard) or equivalent).
| | Sheath | | 4-6 cm | | |
| | | | | | | |
| | Armor | | | | | Solder Side |
| | | | | | |
| | | | | | Screw | | 1 2 |
| Armor | | | | Clamp | Tighten | 3 |
| | | | | |
| | | | | | | set screw | Connect to |
| | | | | | | |
| | Armor | | | | | | "1" and "2". |
| | | | | Connector Housing | 1: AC (L: Live line) |
| | | | | |
| | | | | | 2: AC(N: Neutral line) |
| | | | | | | |
| | | Soldering connector SRCN6A13-3S | |
| | | | | | | | |
Armor
Conductor fS = 1.5 mm2 = 1.56 mm
Sectional view of cable DPYC-1.5
How to solder connector SRCN6A13-3S; sectional view of cable DPYC-1.5
•The cover of the D-sub connector of the cable 06S4078 may be removed to pass the cable through tubing, bulkhead, etc. Use vinyl tape to bind connector wiring and rubber cover. This allows the cable to be passed through a hole having a diameter of 30 mm.
8