Inverter Status Monitoring, Special Registers for Control

(2)Error history (error codes and error definitions) The inverter stores the error codes of the errors that occurred.

The error codes of up to eight errors are stored in the order as shown below and are always read-enabled (write-disabled).

<Error code storing method details>

D9136

b15 to b8

b7 to b0

 

Error history 2

Error history 1

 

Newer

D9137

Error history 4

Error history 3

 

D9138

 

 

 

 

Error history 6

Error history 5

 

D9139

 

 

Older

 

Error history 8

Error history 7

 

Data

Description

 

Data

Description

 

Data

Description

H00

No alarm

 

H90

E.OHT

 

HD2

E.ECT

 

 

 

H91

E.PTC

 

HD3

E.OD

H10

E.OC1

 

 

 

HA0

E.OPT

 

HD5

E.MB1

H11

E.OC2

 

 

 

HA3

E.OP3

 

HD6

E.MB2

H12

E.OC3

 

 

 

HB0

E.PE

 

HD7

E.MB3

H20

E.OV1

 

 

 

HB1

E.PUE

 

HD8

E.MB4

H21

E.OV2

 

 

 

HB2

E.RET

 

HD9

E.MB5

H22

E.OV3

 

 

 

HB3

E.PE2

 

HDA

E.MB6

H30

E.THT

 

 

 

HC0

E.CPU

 

HDB

E.MB7

H31

E.THM

 

 

 

HC1

E.CTE

 

HDC

E.EP

H40

E.FIN

 

 

 

HC2

E.P24

 

HF1

E.1

H50

E.IPF

 

 

 

HC4

E.CDO

 

HF2

E.2

H51

E.UVT

 

 

 

HC5

E.IOH

 

HF3

E.3

H52

E.ILF

 

 

 

HC6

E.SER

 

HF6

E.6

H60

E.OLT

 

 

 

HC7

E.AIE

 

HF7

E.7

H70

E.BE

 

 

 

HC8

E.USB

 

HFB

E.11

H80

E.GF

 

 

 

HD0

E.OS

 

HFD

E.13

H81

E.LF

 

 

 

HD1

E.OSD

 

 

 

 

 

 

 

 