System Configuration

2.1 System Configuration

2.1.1System configuration example

(1)PLC side

Mount the "Control & Communication Link system master/local module" on the main base unit or extension base unit of the PLC CPU that will act as the master station.

(2)Connect the PLC CC-Link module master station and inverters by CC-Link dedicated cables.

Inverter

Master station

Powersupply module

AJ61

CPU

 

BT11

Terminating resistor

Power supply

CC-Link dedicated cable

Up to 42 inverters can be connected when only inverters are connected.

Motor Power supply

Inverter

Motor

REMARKS

Refer to the FR-A7NC indtruction manual for the CC-Link communication wiring and CC-Link cables.