System Configuration

POINT

The difference between CC-Link communication (Pr. 544 = 100, 112, 114, 118) with PLC function and normal CC-Link communication (Pr. 544 =1, 2, 12, 14, 18) is indicated below.

PLC CPU

CC-Link master module

Inverter

Pr.544=0,1,12,14,18

I/O (RX, RY)

Inverter CPU

RWw RWr

PLC CPU

CC-Link master module

Parameter read/write, monitor, operation commands, etc. have been assigned in advance.

Inverter

Pr.544=100,112,114,118

Built-in CC-Link module

 

Built-in

 

I/O (RX, RY)

sequence

 

program

 

 

Inverter CPU

RWw RWr

User

assignment

 

 

 

Using built-in sequence program, parameters, monitor, etc. must be assigned.

Other data read/write, etc. can be assigned freely as user areas.

*Operation and speed commands have been assigned in advance.