Description of devices

(2)Outputs Y

(a)Outputs are designed to output the control results of a program to outside the inverter (signal lamps, digital indicators, magnetic switches (contactors), solenoids, etc.).

(b)An output can be exported to outside the inverter as equivalent to one N/O contact.

(c)There are no restrictions on the number of N/O and N/C contacts of output Yn used in the program, if they are used within the program capacity range.

Sequence No restrictions on the number of used contacts.

 

function

Load

 

M11

Program

Output circuit (external devices)

Fig 3.13 Concept of Outputs (Y)

When no external devices are connected to the control output terminals, "Y" can be used as the internal relay "M".

78

Page 83
Image 83
Mitsubishi Electronics 700 Series, FR-A700 specifications Outputs Y