Sequence Instructions

3.25.10 End Instruction : Sequence program end ... END

 

 

 

 

 

Usable Devices

 

 

 

 

Error

 

Bit devices

 

Word (16-bit) devices

Constants

Level

Digit

Flag

X

 

Y

 

M

T

C

D

K

H

N

Designation

(M9010,

 

 

 

M9011)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

END

Functions

(1)Indicates the end of a program. Execution terminates scanning at this step and returns to step 0.

Sequence program

(2) The END instruction cannot be used halfway through the sequence program.

CAUTION

If the END instruction does not exist in the program, an operation error occurs and the PLC function does not operate.