Sequence Instructions

3.25.8 Shift Instructions : Bit device shift ... SFT, SFTP

 

 

 

Usable Devices

 

 

 

 

Error

 

Bit devices

 

Word (16-bit) devices

Constants

Level

Digit

Flag

X

Y

M

T

C

D

K

H

N

Designation

(M9010,

 

M9011)

 

 

 

 

 

 

 

 

 

 

D

{

{

 

 

 

 

 

 

 

 

SFT commands

Set data

D

Device number to which data will be shifted

Functions

(1)Shifts the ON/OFF status of the device preceding the one specified at D to the specified device, and turns off the preceding device.

(2)Use the SET instruction to turn on the first device from which data will be shifted.

(3)When using the SFT or SFTP instructions consecutively, program in order of larger to smaller device numbers.

Shift range

Shift input

1)

2)

3)

4)

5)

6)

7)

*At M8 to 15, 1 indicates ON and 0 indicates OFF.

X02 ON

After first shift input After second shift input X02 ON

After third shift input After fourth shift input After fifth shift input