Mitsubishi Electronics FR-A700, 700 Series specifications Pid

Models: FR-A700 700 Series

1 183
Download 183 pages 30.92 Kb
Page 24
Image 24

Device Map

Number

 

D9234

 

D9235

 

D9236

 

D9237

 

D9238

 

D9239

 

D9240

controlfor

D9241

D9242

registers

D9243

 

Special

D9244

D9245

 

D9246

 

D9247

 

D9248

 

D9249

 

D9250

 

D9251

 

D9252

 

D9253

 

D9254

 

D9255

 

 

Name

Description

Page

Second

 

 

parameter

When setting the calibration(bias/gain) parameters.

 

changing (RAM)

 

Second

H00: Frequency(toruque)

34, 36

H01: Parameter-set analog value

parameter

H02: Analog value input from terminal

 

changing

 

 

(EEPROM)

 

 

Pulse train input

The number of pulses counted in count cycle is

 

sampling pulse

stored. (0 to 32767)

 

Pulse train input

 

 

cumulative count

 

 

value L

The cumulative value of the number of sampling

 

Pulse train input

pulses is stored. (0 to 99999999)

40

cumulative count

 

value H

 

 

Reset request of

The sampling pulses and cumulative count value are

 

pulse train input

cleared. Automatically changes to "0" after reset.

 

count

(1: count clear)

 

Count start of the

Start counting the sampling pulses and cumulative

 

pulse train input

count value. (0: count stop, 1: count start)

 

Parameter

Set the number of parameter read or written of the

 

number (RAM)

inverter.

 

Parameter

The parameter description of the inverter (RAM value)

 

description

specified by D9241 is stored. Set the parameter

 

(RAM)

setting for parameter write.

34, 36

Parameter

Set the number of parameter read or written of the

number

 

inverter.

 

(EEPROM)

 

 

 

Parameter

The parameter description of the inverter (EEPROM

 

description

value) specified by D9243 is stored. Set the

 

(EEPROM)

parameter setting for parameter write.

 

Terminal 1 input

Analog input value of terminal 1 (0.1% increments) is

 

stored.

 

 

 

Terminal 2 input

Analog input value of terminal 2 (0.1% increments) is

39

stored.

 

 

Terminal 4 input

Analog input value of terminal 4 (0.1% increments) is

 

stored.

 

 

 

PID set point /

Set the PID set point or PID deviation (0.01% units)

 

PID deviation

 

 

 

PID

Set the PID measurement value (0.01% units)

41

measurement

value

 

 

PID manipulated

Stores the PID manipulated variable (0.01% units)

 

variable

 

 

Terminal FM

When Pr. 54 is set to "70", pulse train can be output

 

from terminal FM. High speed pulse train output can

 

output

 

be performed. (0.1% increments)

 

 

 

Terminal AM

When Pr. 158 is set to "70", analog output can be

39

output

performed from terminal AM. (0.1% increments)

 

AM0 output

Analog output can be performed from terminal AM0

 

AM1 output

and AM1 of the FR-A7AY. (0.1% increments)

 

PID operation

Setting 1 starts PID control.

41

control

 

 

Device Map

1

PLC FUNCTION

19

Page 24
Image 24
Mitsubishi Electronics FR-A700, 700 Series specifications Pid