Paluse train input function

1.11 Paluse train input function

Pulse train (the number of sampling pulses) from terminal JOG is stored to D9236. When the sampling pulses overflow, make adjustment with the setting of Pr. 416 and Pr. 417.

The number of sampling pulses

=the number of input pulses per count cycle x Pre-scale setting value (Pr. 417) x increments scaling factor (Pr. 416)

Parameter

Name

Initial

 

Setting

Description

Value

 

Range

 

 

 

 

291

Pulse train input

0

0, 10,20

Terminal JOG

selection

1,11,21,100

Pulse train input

 

 

 

 

 

 

 

Pre-scale function selection

 

 

 

 

 

(increments scaling factor)

 

 

 

 

 

0: No function

416

Pre-scale function

0

 

0 to 5

1: ×1

selection

 

2: ×0.1

 

 

 

 

 

 

 

 

 

3: ×0.01

 

 

 

 

 

4: ×0.001

 

 

 

 

 

5: ×0.0001

 

Pre-scale setting

 

 

 

Set the pre-scale value to calcute the

417

1

 

0 to 32767

number of sampling pulse when

value

 

 

 

 

 

inputting the pulse train.

 

 

 

 

 

 

 

 

 

 

 

Device No.

Name

 

 

Setting

Description

 

 

Range

 

 

 

 

 

D9236

Pulse train input sampling

 

0 to 32767

The number of pulses counted in

 

pulse

 

 

 

count cycle is stored.

D9237

Pulse train input cumulative

 

 

 

count value L

 

 

0 to

The cumulative value of the number

 

 

 

 

 

 

99999999

of sampling pulses is stored.

D9238

Pulse train input cumulative

 

count value H

 

 

 

 

 

 

 

 

 

D9239

Reset request of pulse train

 

0

Not clear

input count

 

 

1

Count clear

 

 

 

D9240

Count start of the pulse train

 

0

Stop counting

input

 

 

1

Start counting

 

 

 

40

Page 45
Image 45
Mitsubishi Electronics 700 Series Paluse train input function, Selection, Device No Name Setting Description Range