Application instructions

2)Program that ANDs the X10-1B and D33 data and outputs the result to Y0-B when XA turns on.

ANDs X10-1B data and D33 data and stores result to D33.

Outputs D33 data to Y0-F.

Coding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

b15

b14

b13

b12

b11

b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D33

X1B X1A X19 X18 X17 X16 X15 X14 X13 X12 X11 X10

X1B to 10

Regarded as 0s.

D33

Turn to 0s.

3)Program that ANDs the X10-1B and D33 data and outputs the result to Y0-B when XA turns on.

Coding

X1B X1A X19 X18 X17 X16 X15 X14 X13 X12 X11 X10

X1B to 10

Regarded as 0s.

b15

 

b14

 

b13

 

b12

 

b11

 

b10

 

b9

 

b8

 

b7

 

b6

 

b5

 

b4

 

b3

 

b2

 

b1

 

b0

D33

YB YA Y9 Y8 Y7 Y6 Y5 Y4 Y3 Y2 Y1 Y0

YB to Y0

Remain unchanged.