Sequence Instructions

MCR

(1)This instruction is designed to reset the master control and indicates the end of the master control range.

(2)Do not provide a contact instruction in front of the MCR instruction.

The master control instructions can be nested. Their master control ranges are differentiated by the nesting (N). The nesting can be used from N0 to N7.

Using the nesting structure, you can create a ladder that restricts the program execution conditions in order.

The ladder using the nesting structure is as shown below.

 

‰ñ ˜H ƒ‚ [￿ hƒ ‚Å ‚Ì •\ Ž¦

 

 

 

 

Actual operation ladder

A

Display in ladder mode

 

 

 

 

Executed when A turns on.

B

Executed when A and B turn on.

C

Executed when A, B and C turn on.

Executed when A and B turn on.

Executed when A turns on.

Irrelevant to A, B and C.