Datalogic Scanning DS2400 manual Inputs, Input NPN command using external power

Page 28

DATALOGIC

DS2400

The RTSAUX and CTSAUX signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the DS2400 activates the RTSAUX output to indicate a message is to be transmitted. The receiving unit activates the CTSAUX input to enable the transmission.

2.4.4 Inputs

The inputs available on the connector supplied with the scanner are the pins relative to the External Trigger, as indicated below:

Pin

Name

Function

 

 

 

18

EXT TRIG+

External Trigger +

19

EXT TRIG-

External Trigger -

The External Trigger input is used in the On-Line Operating Mode and tells the scanner to scan for a code. The active state of this input is selected in software. Refer to the WinHost Help On Line.

The yellow LED (Figure A, 2 ) is on when the External Trigger forces a current flow through the EXT TRIG+ and EXT TRIG- pins.

This input is optocoupled and can be driven by both an NPN or PNP type command. The connections are indicated in the following diagrams:

DS2400

+ 5V

Vext 30 Vdc max. EXTERNAL TRIGGER

18 EXT TRIG+

V

19EXT TRIG-

Signal

Figure 2.19 - Input NPN command using external power

Installation - 2.15

Image 28 Contents
Page Installation Manual DS2400Datalogic S.p.A DS2400-XXXX, Laser Scanner and all its modelsContents Reading Features Guide to Installation DS2400 General ViewLaser Safety Safety PrecautionsStandard Regulations Scanner Figure a Power SupplyModel DS2400-XXX1 Introduction General FeaturesDescription Good Read DS2400 X X X Available ModelsAccessories GFC-2100 Accessory InstallationInstallation Package ContentsMechanical Installation DS2400 Overall dimensionsJunction BOX Installation Junction Box MountingMounting Junction Box Junction Box Electrical Connections System cable connections to the junction boxBox Pinout for DS2400 Name INT-22 OnlyScanner cable connections to the junction box Electrical Connections Power Supply Main Serial InterfaceRS232 Interface Pin Name Function 13 RS232 control signals RS485 Full-Duplex InterfaceRS485 Half-Duplex Interface 14 RS485 full-duplex connectionsMA Current Loop Interface INT-22 Accessory Only CLOUT+Auxiliary RS232 Interface 17 20 mA C.L. connections19 Input NPN command using external power Inputs20 Input NPN command using DS2400 power Outputs Positioning24 Pitch Angle Typical Layouts Point-to-PointPass Through DS2400 Host3 RS232 Master/Slave 30 RS232 Master/Slave layout4 RS485 Master/Slave HostMultiplexer 32 Multiplexer layoutThis page is intentionally left blank Installation STEP-LADDER Mode Reading FeaturesSN = LH/LS * SS 2 Where SN PICKET-FENCE Mode SN = FW-LW/LS * SS -2 Where SNPerformance RasterReading Diagrams ConditionsDS2400-2XXXLong Reading Range This page is intentionally left blank Technical Features Maintenance CleaningDS2400 Technical Features Electrical FeaturesPhysical Features