Paradyne 4200 manual Rtrv-Cond-Eqpt, 10-35, 21. RTRV-COND-EQPT Command Parameters

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 227
Image 227
RTRV-COND-EQPT

10. Fault Commands

RTRV-COND-EQPT

The RTRV-COND-EQPT command retrieves the current condition of specified equipment alarm indicators.

Table 10-21. RTRV-COND-EQPT Command Parameters

RTRV-COND-EQPT:[tid]:aidall_eqpt:[ctag]::[ntfcde],[cond_eqp t];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

The identification of the target NE. TID is optional and has a default

 

value of null. The NE's SID code is the only other valid value.

 

 

aid_eqpt

Access Identifier for a piece of equipment. The value can be preceded

 

with aid=, but this is not required. Grouping is allowed. Valid values are:

 

ALL: All equipment units

 

SHELF-rack-shelf

 

LT-rack-shelf-slot: All LT units in slot

 

LTA-rack-shelf-slot: LT unit A (main card)

 

rack: rack number (1)

 

shelf: shelf number (1)

 

slot: LT slot number (1)

 

Grouping is allowed. If no value is specified, ALL is assumed.

 

 

[ctag]

The correlation tag that correlates an input command with its associated

 

output response(s). It is assigned by the originator of the command. The

 

value is limited to six characters, which may be an identifier or a decimal

 

numeral. It is optional with a default of 0.

 

 

[cond_eqpt]

Equipment condition. Valid values are:

 

EQPT: Equipment failed self-test

 

FANALM-1: Fan alarm for Fan 1

 

FANALM-2: Fan alarm for Fan 2

 

PROGVER: Failed to load or find requested software

 

RMTDLFAIL: Failed to download software

 

SWROLLBACK: Software version rolled back

 

Grouping is allowed. If no value is specified, ALL is assumed.

4200-A2-GB20-00

August 2002

10-35

Page 227
Image 227
Paradyne 4200 manual Rtrv-Cond-Eqpt, 10-35, 21. RTRV-COND-EQPT Command Parameters