Paradyne 4200 manual 10-37, 22. RTRV-COND-EQPT Response Parameters 2 of, Example, Related Commands

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 229
Image 229
Table 10-22. RTRV-COND-EQPT Response Parameters (2 of 2)

10. Fault Commands

Table 10-22. RTRV-COND-EQPT Response Parameters (2 of 2)

Parameter

Explanation

 

 

cond_eqpt

As described for command parameters (see Table 10-21,

 

RTRV-COND-EQPT Command Parameters).

 

 

serveff

Service effect. Valid values are:

 

– SA: Service affecting

 

– NSA: Not service affecting

 

 

[cond_descr]

Description of alarm condition.

 

 

Example

Retrieve current condition of LT alarm indicators.

RTRV-COND-EQPT:TAMPA:LT:42::;

TAMPA 02-04-20 10:30:23

M42 COMPLD

/* RTRV-COND-EQPT:TAMPA:LT:42:: */ "LT:MJ,HITEMP,SA,,,,,,Module temperature exceeded limit"

;

Related Commands

None

4200-A2-GB20-00

August 2002

10-37

Page 229
Image 229
Paradyne 4200 manual 10-37, 22. RTRV-COND-EQPT Response Parameters 2 of, RTRV-COND-EQPTTAMPALT42 TAMPA 02-04-20 M 42 COMPLD