Paradyne 4200 4-13, 10. RTRV-PM-T1 Command Parameters 2 of, Response Format, IP c, Error Response

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 105
Image 105
Table 4-10. RTRV-PM-T1 Command Parameters (2 of 2)

4. DS1 Facility Commands

Table 4-10. RTRV-PM-T1 Command Parameters (2 of 2)

RTRV-PM-T1:[tid]:aid_ds1:[ctag]::[monds1],[monlev],[locn],, [tmper],[mondat],[montm];

[mondat]

Start date for the monitoring period. Valid values are:

 

mm-dd: Month and day

 

– mm: Month (112)

 

– dd: Day (131)

 

ALL: All performance monitoring data is retrieved

 

If no value is specified, today's date is assumed.

 

 

[montm]

Start time for the monitoring period. Valid values are:

hh-mm: Hour and minute

hh: Hour (0023)

mm: Minute. Valid values are 0, 15, 30, and 45.

ALL: All performance monitoring data is retrieved

If no value is specified, the nearest value to the current time is assumed. Grouping is allowed. Statistics will not be aligned with the wall clock. Statistics will be monitored for the interval in which the selected monitoring period falls.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response will be sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* RTRV-PM-T1:[tid]:aid_ds1:[ctag]::[monds1],[monlev], [locn],,[tmper],[mondat],[montm] */

"aid_ds1,[aid_type]:monds1,monval,,[locn],,[tmper], [mondat],[montm]"

;

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* RTRV-PM-T1:[tid]:aid_ds1:[ctag]::[monds1],[monlev],[locn],, [tmper],[mondat],[montm] */

errcde

;